Partial volume correction strategies in PET
In the early days of PET, the partial volume effect (PVE) was identified as a serious factor
affecting image quality and limiting the accuracy of quantitative analysis. Because of the …
affecting image quality and limiting the accuracy of quantitative analysis. Because of the …
Magnetic resonance-guided positron emission tomography image reconstruction
The resolution of positron emission tomography (PET) images is limited by the physics of
positron-electron annihilation and instrumentation for photon coincidence detection. Model …
positron-electron annihilation and instrumentation for photon coincidence detection. Model …
Digimouse: a 3D whole body mouse atlas from CT and cryosection data
We have constructed a three-dimensional (3D) whole body mouse atlas from coregistered x-
ray CT and cryosection data of a normal nude male mouse. High quality PET, x-ray CT and …
ray CT and cryosection data of a normal nude male mouse. High quality PET, x-ray CT and …
Simultaneous reconstruction of activity and attenuation in time-of-flight PET
In positron emission tomography (PET) and single photon emission tomography (SPECT),
attenuation correction is necessary for quantitative reconstruction of the tracer distribution …
attenuation correction is necessary for quantitative reconstruction of the tracer distribution …
Accurate and consistent lesion quantitation with clinically acceptable penalized likelihood images
Clinical widespread use of edge-preserving penalized-likelihood (PL) methods has been
hindered by the properties of the resulting images such as blocky background noise …
hindered by the properties of the resulting images such as blocky background noise …
Analysis of resolution and noise properties of nonquadratically regularized image reconstruction methods for PET
We present accurate and efficient methods for estimating the spatial resolution and noise
properties of nonquadratically regularized image reconstruction for positron emission …
properties of nonquadratically regularized image reconstruction for positron emission …
[HTML][HTML] Quantitative statistical methods for image quality assessment
Quantitative measures of image quality and reliability are critical for both qualitative
interpretation and quantitative analysis of medical images. While, in theory, it is possible to …
interpretation and quantitative analysis of medical images. While, in theory, it is possible to …
Efficient estimation of the PDF and the CDF of the exponentiated Gumbel distribution
SF Bagheri, M Alizadeh… - … in Statistics-Simulation and …, 2016 - Taylor & Francis
The exponentiated Gumbel model has been shown to be useful in climate modeling
including global warming problem, flood frequency analysis, offshore modeling, rainfall …
including global warming problem, flood frequency analysis, offshore modeling, rainfall …
Regularization design in penalized maximum-likelihood image reconstruction for lesion detection in 3D PET
Detecting cancerous lesions is a major clinical application in emission tomography. In
previous work, we have studied penalized maximum-likelihood (PML) image reconstruction …
previous work, we have studied penalized maximum-likelihood (PML) image reconstruction …
A Bayesian MAP-EM algorithm for PET image reconstruction using wavelet transform
J Zhou, JL Coatrieux, A Bousse… - IEEE Transactions on …, 2007 - ieeexplore.ieee.org
In this paper, we present a PET reconstruction method using the wavelet-based maximum a
posteriori (MAP) expectation-maximization (EM) algorithm. The proposed method, namely …
posteriori (MAP) expectation-maximization (EM) algorithm. The proposed method, namely …