Turnitin
降AI改写
早检测系统
早降重系统
Turnitin-UK版
万方检测-期刊版
维普编辑部版
Grammarly检测
Paperpass检测
checkpass检测
PaperYY检测
A practical approach for distribution network load balancing by optimal re‐phasing of single phase customers using discrete genetic algorithm
Voltage and current imbalance have adverse impacts on power systems such as power loss
increase, communication interference, and component lifetime reduction. This paper …
increase, communication interference, and component lifetime reduction. This paper …
Loss partitioning and loss allocation in three-phase radial distribution systems with distributed generation
E Carpaneto, G Chicco… - IEEE Transactions on …, 2008 - ieeexplore.ieee.org
In this paper, the concepts related to loss partitioning among the phase currents in three-
phase distribution systems are revisited in the light of new findings identified by the authors …
phase distribution systems are revisited in the light of new findings identified by the authors …
Fault analysis in four-wire distribution networks
The neutral wire in most existing power flow and fault analysis software is usually merged
into phase wires using Kron's reduction method. In some applications, such as fault analysis …
into phase wires using Kron's reduction method. In some applications, such as fault analysis …
Impedance modelling for european style distribution feeder
A Koirala, R D'hulst… - … Conference on Smart …, 2019 - ieeexplore.ieee.org
This paper discusses the methods of modelling a European style TT grounded low voltage
(LV) distribution system without increasing computational complexity and with increased …
(LV) distribution system without increasing computational complexity and with increased …
[PDF][PDF] Evolution of distribution system load flow methods-a bibliographic review
Load flow methods for power distribution systems are quite different in comparison to
transmission systems owing to some special topological features. Over years various load …
transmission systems owing to some special topological features. Over years various load …
Rural Single Wire Earth Return distribution networks–Associated problems and cost-effective solutions
Single Wire Earth Return (SWER) systems are used for supplying electricity at low cost,
where electricity supply is required for small populations of people dispersed across wide …
where electricity supply is required for small populations of people dispersed across wide …
Potential for increased rural electrification rate in sub-Saharan Africa using SWER power distribution networks
Rural electrification rate (RER) in Africa is still low to date. Several countries in Sub-Saharan
Africa have tried to address this problem using conventional single-phase two-wire or three …
Africa have tried to address this problem using conventional single-phase two-wire or three …
[PDF][PDF] Effect of an optimal conductor size selection scheme for single wire earth return power distribution networks for rural electrification
This research presents an improved optimal conductor size selection scheme for single wire
earth return (SWER) in power distribution networks for rural electrification. The power …
earth return (SWER) in power distribution networks for rural electrification. The power …
Models for conductor size selection in single wire earth return distribution networks
G Bakkabulindi, MR Hesamzadeh, M Amelin… - 2013 …, 2013 - ieeexplore.ieee.org
The use of the ground as the current return path often presents planning and operational
challenges in power distribution networks. This study presents optimization-based models …
challenges in power distribution networks. This study presents optimization-based models …
4-Wire load flow analysis of a representative urban network incoprating SSEG
KM Sunderland, MF Conlon - 2012 47th International …, 2012 - ieeexplore.ieee.org
The effect of increased connections of micro generation technologies can only be truly
analysed if accurate distribution network models are used. Such models must be 4-wire …
analysed if accurate distribution network models are used. Such models must be 4-wire …