Turnitin
降AI改写
早检测系统
早降重系统
Turnitin-UK版
万方检测-期刊版
维普编辑部版
Grammarly检测
Paperpass检测
checkpass检测
PaperYY检测
[KNYGA][B] The illustrated wavelet transform handbook: introductory theory and applications in science, engineering, medicine and finance
PS Addison - 2017 - taylorfrancis.com
This second edition of The Illustrated Wavelet Transform Handbook: Introductory Theory and
Applications in Science, Engineering, Medicine and Finance has been fully updated and …
Applications in Science, Engineering, Medicine and Finance has been fully updated and …
Dynamics of the vertically restrained rocking column
This paper investigates the rocking response of a slender column that is vertically restrained
with an elastic tendon that passes through its centerline. Following a variational formulation …
with an elastic tendon that passes through its centerline. Following a variational formulation …
An analytical model of a deformable cantilever structure rocking on a rigid surface: experimental validation
R Truniger, MF Vassiliou… - … engineering & structural …, 2015 - Wiley Online Library
This paper describes an experimental program to examine the dynamic response of
deformable cantilevers rocking on a rigid surface. The primary goal of the tests is to verify …
deformable cantilevers rocking on a rigid surface. The primary goal of the tests is to verify …
A novel stochastic linearization framework for seismic demand estimation of hysteretic MDOF systems subject to linear response spectra
This paper proposes a novel computationally economical stochastic dynamics framework to
estimate the peak inelastic response of yielding structures modelled as nonlinear multi …
estimate the peak inelastic response of yielding structures modelled as nonlinear multi …
[HTML][HTML] The MDOF equivalent linear system and its applications in seismic analysis and design of framed structures
This paper reviews the applications of the multi degree-of-freedom (MDOF) equivalent linear
system in seismic analysis and design of planar steel and reinforced concrete framed …
system in seismic analysis and design of planar steel and reinforced concrete framed …
Non-iterative computational model for fiber-reinforced elastomeric isolators
In this paper, time history analyses are carried out on a structure seismically isolated with
fiber-reinforced elastomeric isolators (FREIs). The lateral response of the isolators is …
fiber-reinforced elastomeric isolators (FREIs). The lateral response of the isolators is …
Equivalent viscous dam** of bilinear hysteretic oscillators
T Liu, T Zordan, Q Zhang… - Journal of Structural …, 2015 - ascelibrary.org
An improved formula to determine the equivalent viscous dam** ratio of a single-degree-
of-freedom (SDOF) bilinear oscillator is proposed in this paper, which simultaneously …
of-freedom (SDOF) bilinear oscillator is proposed in this paper, which simultaneously …
AP/VP specific equivalent viscous dam** model for base-isolated buildings characterized by SDOF systems
T Liu, Q Zhang - Engineering Structures, 2016 - Elsevier
In this paper, an AP/VP specific equivalent viscous dam** model is proposed through
regression analysis to predict the maximum inelastic displacement of base-isolated …
regression analysis to predict the maximum inelastic displacement of base-isolated …
Jacobsen's equivalent dam** concept revisited
GA Papagiannopoulos - Soil Dynamics and Earthquake Engineering, 2018 - Elsevier
The equivalent dam** concept originally proposed by Lydik Jacobsen in 1930 is revisited
in order to be of use in the seismic analysis of building structures. After briefly recalling that …
in order to be of use in the seismic analysis of building structures. After briefly recalling that …
Evaluating the accuracy of an equivalent linear model in predicting peak displacement of seismic isolation systems using single friction pendulum bearings
This study evaluates the accuracy of an equivalent linear model in predicting peak nonlinear
time-history displacement of seismic isolation systems with single friction pendulum …
time-history displacement of seismic isolation systems with single friction pendulum …