Turnitin
降AI改写
早检测系统
早降重系统
Turnitin-UK版
万方检测-期刊版
维普编辑部版
Grammarly检测
Paperpass检测
checkpass检测
PaperYY检测
Active neural interface circuits and systems for selective control of peripheral nerves: a review
Interfaces with peripheral nerves have been widely developed to enable bioelectronic
control of neural activity. Peripheral nerve neuromodulation shows great potential in …
control of neural activity. Peripheral nerve neuromodulation shows great potential in …
A miniaturized wireless neural implant with body-coupled power delivery and data transmission
This article presents a wireless neural implant with body-coupled (BC) data transmission
and power delivery for freely behaving animals and incorporates a precision front end for …
and power delivery for freely behaving animals and incorporates a precision front end for …
Seizure detection and prediction by parallel memristive convolutional neural networks
During the past two decades, epileptic seizure detection and prediction algorithms have
evolved rapidly. However, despite significant performance improvements, their hardware …
evolved rapidly. However, despite significant performance improvements, their hardware …
A survey on underwater wireless power and data transfer system
This research extensively explores contemporary techniques in Underwater Wireless Power
and Data Transfer (WPDT), as found in recent literature over the past 5 years. These …
and Data Transfer (WPDT), as found in recent literature over the past 5 years. These …
A wide-dynamic-range neural-recording IC with automatic-gain-controlled AFE and CT dynamic-zoom ΔΣ ADC for saturation-free closed-loop neural interfaces
This article presents a neural-recording IC with automatic gain control (AGC) according to
the input signal level. AGC enhances the dynamic range (DR) of the recording IC by more …
the input signal level. AGC enhances the dynamic range (DR) of the recording IC by more …
A battery-free neural-recording chip achieving 5.5 cm fully-implanted depth by galvanically-switching passive body channel communication
Y Shen, C Yang, Y Zhang, W Wang… - IEEE Journal of Solid …, 2024 - ieeexplore.ieee.org
Wireless fully implanted devices are widely adopted for long-term neural-recording
applications, where the cable-induced infection risk can be avoided. Battery-free …
applications, where the cable-induced infection risk can be avoided. Battery-free …
Implantable Medical Devices for Wireless Optical Neuromodulation and Neural Recording: Energy-Efficient Integrated Circuit and System Design
Since the development of the first cardiac pacemaker implant in 1958, implantable medical
devices (IMDs) have assumed a critical role across a broad spectrum of clinical …
devices (IMDs) have assumed a critical role across a broad spectrum of clinical …
A 63 μg/√ Hz noise floor and 14 pJ power efficiency open-loop MEMS capacitive accelerometer using closed-loop hybrid dynamic amplifier
L Zhong, S Liu, D Xu, Z Zhu - IEEE Transactions on Circuits and …, 2023 - ieeexplore.ieee.org
MEMS capacitive accelerometer for the Internet of Things (IoT) applications is designed with
open-loop structure rather than close-loop structure to achieve low power consumption. In …
open-loop structure rather than close-loop structure to achieve low power consumption. In …
Fascicle-selective ultrasound-powered bidirectional wireless peripheral nerve interface IC
This paper presents an innovative, minimally invasive, battery-free, wireless, peripheral
nervous system (PNS) neural interface, which seamlessly integrates a millimeter-scale …
nervous system (PNS) neural interface, which seamlessly integrates a millimeter-scale …
A high precision, wide dynamic range closed-loop neuromodulation IC with rapid stimulation artifact recovery
This article presents a high precision, wide dynamic range (DR) closed-loop
neuromodulation (CLNM) system that can completely reject stimulation artifacts (SA) and …
neuromodulation (CLNM) system that can completely reject stimulation artifacts (SA) and …