Defining the systematic and random multipole errors for Main Injector tracking

FA Harfoush, BC Brown, HD Glass… - Proceedings of …, 1993 - ieeexplore.ieee.org
At the Fermilab Magnet Test Facility (MTF) measurements of magnet field shape and
strength have been performed. The tracking of the Fermilab Main Injector (FMI) lattice …

Correction schemes to improve the dynamical aperture of the Main Injector

CS Mishra, FA Haroush - Proceedings of International …, 1993 - ieeexplore.ieee.org
Tracking simulations have revealed that the dominant factor limiting the dynamical aperture
of the Main Injector are the large octupole component and the random errors in the recycled …

[PDF][PDF] Effects of Magnetic Multipoles on Main Injector Lattice

CS Mishra - Part. Accel., 1996 - cds.cern.ch
In this paper we discus the effects of higher order multipoles and magnetic element
misalignments on the Main Injector lattice parameters. These higher order multipoles limits …

[PDF][PDF] Study of the Fermilab Main Injector Lattice

CS Mishra, FA Harfoush - MI notes, 1993 - beamdocs.fnal.gov
Abstract The Fermilab Main Injector is a new 150 GeV protron synchrotron, designed to
remove the limitations of the Main Ring in the delivery of high intensity proton and antiproton …

Study of stability of beam in the Fermilab Main Injector

CS Mishra, F Harfoush - AIP Conference Proceedings, 1992 - pubs.aip.org
The Fermilab Main Injector is a new 150‐GeV proton synchrotron, designed to replace the
Main Ring and improve the high energy physics potential of Fermilab. The status of the …

[PDF][PDF] Study of the Alignment Tolerance and corrector strength in the Fermilab Main Injector Lattice

CS Mishra - 1994 - beamdocs.fnal.gov
The multipurpose opertation of the Fermilab Main Injector (FM1) requires that orbit of the
trajecting particle be as smooth as possible. In this paper we discuss the study of alignment …

Simulation of slow extraction in the Main Injector

CS Mishra, FA Harfoush… - … Conference on Particle …, 1993 - ieeexplore.ieee.org
Recent modifications to the tracking code TEAPOT have allowed us to simulate both ramp
and slow extraction in the Fermilab Main Injector at 120 GeV/c. This calculation includes all …

[PDF][PDF] Study of the Fermilab Main Injector

CS Mishra, FA Harfoush - 1993 - beamdocs.fnal.gov
Abstract The Fermilab Main Injector is a new 150 GeV protron synchrotron, designed to
remove the limitations of the Main Ring in the delivery of high intensity proton and antiproton …