Multibody kinematics optimization for the estimation of upper and lower limb human joint kinematics: a systematized methodological review

M Begon, MS Andersen… - Journal of …, 2018 - asmedigitalcollection.asme.org
Multibody kinematics optimization (MKO) aims to reduce soft tissue artefact (STA) and is a
key step in musculoskeletal modeling. The objective of this review was to identify the …

Soft tissue artifact causes significant errors in the calculation of joint angles and range of motion at the hip

NM Fiorentino, PR Atkins, MJ Kutschke, JM Goebel… - Gait & posture, 2017 - Elsevier
Soft tissue movement between reflective skin markers and underlying bone induces errors in
gait analysis. These errors are known as soft tissue artifact (STA). Prior studies have not …

Standardization proposal of soft tissue artefact description for data sharing in human motion measurements

A Cereatti, T Bonci, M Akbarshahi, K Aminian… - Journal of …, 2017 - Elsevier
Soft tissue artefact (STA) represents one of the main obstacles for obtaining accurate and
reliable skeletal kinematics from motion capture. Many studies have addressed this issue …

Surface marker cluster translation, rotation, scaling and deformation: Their contribution to soft tissue artefact and impact on knee joint kinematics

DL Benoit, M Damsgaard, MS Andersen - Journal of biomechanics, 2015 - Elsevier
When recording human movement with stereophotogrammetry, skin deformation and
displacement (soft tissue artefact; STA) inhibits surface markers' ability to validly represent …

Soft tissue artifact causes underestimation of hip joint kinematics and kinetics in a rigid-body musculoskeletal model

NM Fiorentino, PR Atkins, MJ Kutschke… - Journal of …, 2020 - Elsevier
Rigid body musculoskeletal models have been applied to study kinematics, moments,
muscle forces, and joint reaction forces in the hip. Most often, models are driven with …

Soft tissue displacement over pelvic anatomical landmarks during 3-D hip movements

V Camomilla, T Bonci, A Cappozzo - Journal of Biomechanics, 2017 - Elsevier
The position, in a pelvis-embedded anatomical coordinate system, of skin points located
over the following anatomical landmarks (AL) was determined while the hip assumed …

Development and validation of subject-specific pediatric multibody knee kinematic models with ligamentous constraints

M Barzan, L Modenese, CP Carty, S Maine… - Journal of …, 2019 - Elsevier
Computational knee models that replicate the joint motion are important tools to discern
difficult-to-measure functional joint biomechanics. Numerous knee kinematic models of …

Loads in the hip joint during physically demanding occupational tasks: A motion analysis study

PA Varady, U Glitsch, P Augat - Journal of biomechanics, 2015 - Elsevier
Epidemiologic studies of osteoarthritis of the hip indicate a possible connection between
work related activities and the pathogenesis of the disease. This study investigated the hip …

A practical gait feedback method based on wearable inertial sensors for a drop foot assistance device

L Meng, U Martinez-Hernandez, C Childs… - IEEE Sensors …, 2019 - ieeexplore.ieee.org
To maximise the efficiency of gait interventions, gait phase and joint kinematics are
important for closing the system loop of adaptive robotic control. However, few studies have …

IMU-based sensor-to-segment multiple calibration for upper limb joint angle measurement—A proof of concept

M Zabat, A Ababou, N Ababou, R Dumas - Medical & biological …, 2019 - Springer
A lot of attention has been paid to wearable inertial sensors regarded as an alternative
solution for outdoor human motion tracking. Relevant joint angles can only be calculated …