Turnitin
降AI改写
早检测系统
早降重系统
Turnitin-UK版
万方检测-期刊版
维普编辑部版
Grammarly检测
Paperpass检测
checkpass检测
PaperYY检测
Time-resolved particle image velocimetry
SJ Beresh - Measurement Science and Technology, 2021 - iopscience.iop.org
Time-resolved particle image velocimetry (TR-PIV) has become widespread in fluid
dynamics. Essentially a velocity field movie, the dynamic content provides temporal as well …
dynamics. Essentially a velocity field movie, the dynamic content provides temporal as well …
Measurement in opaque flows: a review of measurement techniques for dispersed multiphase flows
C Poelma - Acta Mechanica, 2020 - Springer
A review is presented of measurement techniques to characterise dispersed multiphase
flows, which are not accessible by means of conventional optical techniques. The main …
flows, which are not accessible by means of conventional optical techniques. The main …
Ultrafast ultrasound vector Doppler for small vasculature imaging
S Yan, J Shou, J Yu, J Song, Y Mao… - IEEE Transactions on …, 2023 - ieeexplore.ieee.org
Ultrafast Doppler has been accepted as a novel modality for small vasculature imaging with
high sensitivity, high spatiotemporal resolution, and high penetration. However, the …
high sensitivity, high spatiotemporal resolution, and high penetration. However, the …
A comprehensive review on CFD simulations of left ventricle hemodynamics: numerical methods, experimental validation techniques, and emerging trends
Globally, high death rates due to heart failure are an essential topic in medical research.
Cardiovascular disease is the leading cause of cardiac dysfunction and collapse, with high …
Cardiovascular disease is the leading cause of cardiac dysfunction and collapse, with high …
High-versatility left ventricle pump and aortic mock circulatory loop development for patient-specific hemodynamic in vitro analysis
E Vignali, E Gasparotti, A Mariotti, D Haxhiademi… - ASAIO …, 2022 - journals.lww.com
The importance of experimental setups able to reproduce cardiac functions was well
established in the field of clinical innovations. The mock circulatory loops acquired rising …
established in the field of clinical innovations. The mock circulatory loops acquired rising …
Use of 3D anatomical models in mock circulatory loops for cardiac medical device testing
Abstract Introduction Mock circulatory loops (MCLs) are mechanical representations of the
cardiovascular system largely used to test the hemodynamic performance of cardiovascular …
cardiovascular system largely used to test the hemodynamic performance of cardiovascular …
[HTML][HTML] Contrast-enhanced high-frame-rate ultrasound imaging of flow patterns in cardiac chambers and deep vessels
Cardiac function and vascular function are closely related to the flow of blood within. The
flow velocities in these larger cavities easily reach 1 m/s, and generally complex …
flow velocities in these larger cavities easily reach 1 m/s, and generally complex …
High-frame-rate contrast-enhanced ultrasound particle image velocimetry in patients with a stented superficial femoral artery: a feasibility study
M van Helvert, S Engelhard, J Voorneveld… - European radiology …, 2022 - Springer
Background Local blood flow affects vascular disease and outcomes of endovascular
treatment, but quantifying it is challenging, especially inside stents. We assessed the …
treatment, but quantifying it is challenging, especially inside stents. We assessed the …
[HTML][HTML] Numerical simulations of flow patterns in the human left ventricle model with a novel dynamic mesh morphing approach based on radial basis function
F Xu, S Kenjereš - Computers in Biology and Medicine, 2021 - Elsevier
We present a new numerical simulation framework for prediction of flow patterns in the
human left ventricle model. In this study, a radial basis function (RBF) mesh morphing …
human left ventricle model. In this study, a radial basis function (RBF) mesh morphing …
Time-resolved wall shear rate map** using high-frame-rate ultrasound imaging
AJY Chee, CK Ho, BYS Yiu… - IEEE Transactions on …, 2022 - ieeexplore.ieee.org
In atherosclerosis, low wall shear stress (WSS) is known to favor plaque development, while
high WSS increases plaque rupture risk. To improve plaque diagnostics, WSS monitoring is …
high WSS increases plaque rupture risk. To improve plaque diagnostics, WSS monitoring is …