Design of a bone-guided cochlear implant microsystem with monopolar biphasic multiple stimulations and evoked compound action potential acquisition and its in …
SH Wang, YK Huang, CY Chen… - IEEE Journal of Solid …, 2021 - ieeexplore.ieee.org
A CMOS bone-guided cochlear implant (BGCI) microsystem is proposed and verified. In the
implanted System on Chip (SoC) of the proposed BGCI, the evoked compound action …
implanted System on Chip (SoC) of the proposed BGCI, the evoked compound action …
A wirelessly powered reconfigurable FDD radio with on-chip antennas for multi-site neural interfaces
This article presents a fully integrated, wireless, RF-powered data transceiver for high-
performance implants, such as neural interfaces. The design occupies a total volume of 1.6 …
performance implants, such as neural interfaces. The design occupies a total volume of 1.6 …
Design and In Vivo Verification of a CMOS Bone-Guided Cochlear Implant Microsystem
Objective: To develop and verify a CMOS bone-guided cochlear implant (BGCI) microsystem
with electrodes placed on the bone surface of the cochlea and the outside of round window …
with electrodes placed on the bone surface of the cochlea and the outside of round window …
Design of stage-selective negative voltage generator to improve on-chip power conversion efficiency for neuron stimulation
SP Lin, MD Ker - IEEE Transactions on Circuits and Systems I …, 2020 - ieeexplore.ieee.org
Dedicated to neuron stimulation circuits, a stage-selective negative voltage generator is
proposed to enhance the overall power efficiency. Since the supplied voltage of the stimulus …
proposed to enhance the overall power efficiency. Since the supplied voltage of the stimulus …
Design of dual-mode stimulus chip with built-in high voltage generator for biomedical applications
TY Yen, MD Ker - IEEE Transactions on Biomedical Circuits …, 2020 - ieeexplore.ieee.org
In this work, a dual-mode stimulus chip with a built-in high voltage generator was proposed
to offer a broad-range current or voltage stimulus patterns for biomedical applications. With …
to offer a broad-range current or voltage stimulus patterns for biomedical applications. With …
CMOS high-efficiency wireless battery charging system with global power control through backward data telemetry for implantable medical devices
CY Wu, SH Wang, LY Tang - IEEE Transactions on Circuits and …, 2020 - ieeexplore.ieee.org
A high-efficiency CMOS wireless battery charging system with battery voltage tracking and
global power control through the proposed pulsed load-shift keying (PLSK) backward data …
global power control through the proposed pulsed load-shift keying (PLSK) backward data …
Design of multiple-charge-pump system for implantable biomedical applications
SP Lin, MD Ker - 2018 IEEE Biomedical Circuits and Systems …, 2018 - ieeexplore.ieee.org
Circuit design to implement a multiple-charge-pump (MCP) system in a low-voltage standard
CMOS process is proposed, that can successfully support the desired power sources for …
CMOS process is proposed, that can successfully support the desired power sources for …
Reliable and efficient parallel checkpointing framework for nonvolatile processor with concurrent peripherals
Intermittent systems powered by ambient energy harvesting are becoming popular for the
benefits of an infinite lifetime and minimum maintenance requirements. Nonvolatile …
benefits of an infinite lifetime and minimum maintenance requirements. Nonvolatile …
DC-DC boost converter for wireless power transfer systems
This paper presents a DC-DC boost converter for wireless power transfer systems to treat
tinnitus patients. The proposed regulated charge-pump based DC-DC boost converter circuit …
tinnitus patients. The proposed regulated charge-pump based DC-DC boost converter circuit …
Improved design and in vivo animal tests of bone-guided cochlear implant microsystem with monopolar biphasic multiple stimulation and neural action potential …
SH Wang, YK Huang, CY Chen, CF Lee… - 2020 IEEE Asian …, 2020 - ieeexplore.ieee.org
In this paper, an improved design of implantable SoC with monopolar biphasic constant
current stimulation (CCS), double-electrode multiple stimulation, and the evoked compound …
current stimulation (CCS), double-electrode multiple stimulation, and the evoked compound …