[HTML][HTML] A comprehensive review of fault diagnosis and prognosis techniques in high voltage and medium voltage electrical power lines

M Bindi, MC Piccirilli, A Luchetta, F Grasso - Energies, 2023 - mdpi.com
This paper presents an extensive review of the most effective and modern monitoring
methods for electrical power lines, with particular attention to high-voltage (HV) and medium …

Fault current limiters in power systems: A comprehensive review

MS Alam, MAY Abido, I El-Amin - Energies, 2018 - mdpi.com
Power systems are becoming more and more complex in nature due to the integration of
several power electronic devices. Protection of such systems and augmentation of reliability …

Transient stability constrained protection coordination for distribution systems with DG

TS Aghdam, HK Karegar… - IEEE Transactions on …, 2017 - ieeexplore.ieee.org
Overcurrent relays are the main protective devices used in distribution networks. High relay
operating times coupled with the low inertia time constant of distributed generations (DGs) …

[HTML][HTML] A novel configuration approach of SFCLs in the power grid and its economic analysis

B Li, Q Wu, C Li, Y Ou, J Zhu, P Chen, D Wei… - International Journal of …, 2024 - Elsevier
The superconducting fault current limiter (SFCL) is expected to be a good choice for
cooperating the circuit breakers to cut off large fault current. In order to achieve better …

Application of a SFCL for fault ride-through capability enhancement of DG in a microgrid system and relay protection coordination

H He, L Chen, T Yin, Z Cao, J Yang… - IEEE Transactions on …, 2016 - ieeexplore.ieee.org
Concerning that a short-circuit fault happens inside a microgrid system, parts of distributed
generation (DG) units may not meet the fault ride-through (FRT) requirements and will be …

Protection of active distribution networks with conventional and inverter-based distributed generators

SF Zarei, S Khankalantary - International Journal of Electrical Power & …, 2021 - Elsevier
Fault current limiter (FCL) is one of the best choices for solving protection problems in active
distribution networks comprising dispersed generation (DG). Due to the nonlinear nature of …

A novel methodology in optimal setting of directional fault current limiter and protection of the MG

M Farzinfar, M Jazaeri - International Journal of Electrical Power & Energy …, 2020 - Elsevier
Abstract Integration of the Distributed Generators (DGs) in the MicroGrid (MG) provides an
additional contribution to the fault current causing change of the short circuit current which …

Real-time coordinated control of low-voltage DC distribution network with soft opening point

S Mudaliyar, S Mishra - IEEE Transactions on Power …, 2020 - ieeexplore.ieee.org
In low-voltage dc distribution networks (DDNs), the load terminals typically employ voltage-
source inverters to provide ac supply to the consumers. These load terminals can potentially …

[HTML][HTML] Impacts of a flux-coupling SFCL on the overcurrent protection for distribution system with infeed

C Li, S Wang, B Li, Q Wu, J Zhu, H Zhang… - International Journal of …, 2023 - Elsevier
With the rapid development of distribution system and the integration of distributed
generations, the increasing fault current is threatening electrical equipment of the power …

[HTML][HTML] Protection coordination of properly sized and placed distributed generations–methods, applications and future scope

S Katyara, L Staszewski, Z Leonowicz - Energies, 2018 - mdpi.com
The radial distribution networks are designed for unidirectional power flows and are passive
in nature. However, with the penetration of Distributed Generation (DG), the power flow …