On the modeling of biomechanical systems for human movement analysis: a narrative review

I Roupa, MR da Silva, F Marques… - … Methods in Engineering, 2022 - Springer
The rising importance of movement analysis led to the development of more complex
biomechanical models to describe in detail the human motion patterns. The models scaled …

Use of optical motion capture for the analysis of normative upper body kinematics during functional upper limb tasks: A systematic review

AM Valevicius, PY Jun, JS Hebert, AH Vette - Journal of electromyography …, 2018 - Elsevier
Quantifying three-dimensional upper body kinematics can be a valuable method for
assessing upper limb function. Considering that kinematic model characteristics, performed …

Dynamic measurements of three-dimensional scapular kinematics: a validation study

AR Karduna, PW McClure… - J. Biomech …, 2001 - asmedigitalcollection.asme.org
The validation of two noninvasive methods for measuring the dynamic three-dimensional
kinematics of the human scapula with a magnetic tracking device is presented. One method …

A method for determination of upper extremity kinematics

G Rab, K Petuskey, A Bagley - Gait & posture, 2002 - Elsevier
Kinematic analysis of the upper extremity has been conducted using a wide variety of
techniques, philosophies, and analytic methods. We describe a simple, marker-based three …

Complete 3D kinematics of upper extremity functional tasks

CJ van Andel, N Wolterbeek, CAM Doorenbosch… - Gait & posture, 2008 - Elsevier
Upper extremity (UX) movement analysis by means of 3D kinematics has the potential to
become an important clinical evaluation method. However, no standardized protocol for …

Effects of upper trunk rotation on shoulder joint torque among baseball pitchers of various levels

AL Aguinaldo, J Buttermore… - Journal of applied …, 2007 - journals.humankinetics.com
High rotational torques during baseball pitching are believed to be linked to most overuse
injuries at the shoulder. This study investigated the effects of trunk rotation on shoulder …

Ambulatory measurement of shoulder and elbow kinematics through inertial and magnetic sensors

AG Cutti, A Giovanardi, L Rocchi, A Davalli… - Medical & biological …, 2008 - Springer
Inertial and magnetic measurement systems (IMMSs) are a new generation of motion
analysis systems which may diffuse the measurement of upper-limb kinematics to …

Reproducibility and minimal detectable change of three-dimensional kinematic analysis of reaching tasks in people with hemiparesis after stroke

JM Wagner, JA Rhodes, C Patten - Physical therapy, 2008 - academic.oup.com
Background and Purpose Three-dimensional kinematic analysis of reaching has emerged
as an evaluative measure of upper-extremity motor performance in people after stroke …

Validation of the Leap Motion Controller using markered motion capture technology

AH Smeragliuolo, NJ Hill, L Disla, D Putrino - Journal of biomechanics, 2016 - Elsevier
Abstract The Leap Motion Controller (LMC) is a low-cost, markerless motion capture device
that tracks hand, wrist and forearm position. Integration of this technology into healthcare …

Movement biomechanics goes upwards: from the leg to the arm

G Rau, C Disselhorst-Klug, R Schmidt - Journal of biomechanics, 2000 - Elsevier
The analysis of lower limb movements has been well established in biomechanics research
and clinical applications for a long time. For these studies, powerful and very advanced tools …