Turnitin
降AI改写
早检测系统
早降重系统
Turnitin-UK版
万方检测-期刊版
维普编辑部版
Grammarly检测
Paperpass检测
checkpass检测
PaperYY检测
Anomaly-based detection of cyberattacks on line current differential relays
Currently, the architecture of Line Current Differential Relays (LCDRs) is designed to
respond to internal faults on the protected line using local and remotely-communicated …
respond to internal faults on the protected line using local and remotely-communicated …
Current-transformer saturation compensation for transformer differential relays
Current-transformer (CT) saturation threatens accurate discrimination between internal fault
current and magnetizing inrush current of a transformer and endangers the proper operation …
current and magnetizing inrush current of a transformer and endangers the proper operation …
Fast detection and compensation of current transformer saturation using extended Kalman filter
In this paper, an efficient method based on the Kalman filter (KF) theory is proposed for fast
and accurate detection and compensation of current transformer (CT) saturation. During the …
and accurate detection and compensation of current transformer (CT) saturation. During the …
Current-transformer saturation detection using savitzky-golay filter
BM Schettino, CA Duque… - IEEE Transactions on …, 2016 - ieeexplore.ieee.org
A new application of the Savitzky-Golay (SG) filters in current-transformer saturation
detection is proposed. The ability of the SG filters to handle noisy signals improves the …
detection is proposed. The ability of the SG filters to handle noisy signals improves the …
CT saturation detection and compensation: A hybrid physical model-and data-driven method
Current transformer (CT) saturation is one of the dominant causes of relay protection
devices' malfunctions, which pose a threat to the safe operation of the power system. To …
devices' malfunctions, which pose a threat to the safe operation of the power system. To …
Detection of current transformer saturation based on variational mode decomposition analysis
AA Abdoos - IET Generation, Transmission & Distribution, 2016 - Wiley Online Library
Sometimes, current transformers (CTs) are saturated in power systems due to increase of
flux passing through the CT core. The distorted CT secondary current can lead to …
flux passing through the CT core. The distorted CT secondary current can lead to …
Adaptive CWT‐based overcurrent protection for smart distribution grids considering CT saturation and high‐impedance fault
In this study, an adaptive continuous wavelet transform (CWT)‐based overcurrent protection
for smart grids is proposed to enhance the overcurrent protection performance encountering …
for smart grids is proposed to enhance the overcurrent protection performance encountering …
Current-transformer saturation prevention using a controlled voltage-source compensator
Current-transformer (CT) saturation causes severe distortion in the measured current
waveform which may lead to maloperation of the protective devices. This paper proposes a …
waveform which may lead to maloperation of the protective devices. This paper proposes a …
Detection of current transformer saturation phenomenon for secured operation of smart power network
Any secured operation of smart grid highly depends on the signal transmitted through
Intelligent Electronic Device (IED) to/from the external source. For this, the healthy operation …
Intelligent Electronic Device (IED) to/from the external source. For this, the healthy operation …
Evaluation of various dynamics on current transformer saturation with a model study on power system protection
Now a day most power system protective schemes are incorporated with a current
transformer (CT) to reduce the current level of the power system, especially during heavy …
transformer (CT) to reduce the current level of the power system, especially during heavy …