Turnitin
降AI改写
早检测系统
早降重系统
Turnitin-UK版
万方检测-期刊版
维普编辑部版
Grammarly检测
Paperpass检测
checkpass检测
PaperYY检测
RF coils: A practical guide for nonphysicists
Radiofrequency (RF) coils are an essential MRI hardware component. They directly impact
the spatial and temporal resolution, sensitivity, and uniformity in MRI. Advances in RF …
the spatial and temporal resolution, sensitivity, and uniformity in MRI. Advances in RF …
The state-of-the-art and emerging design approaches of double-tuned RF coils for X-nuclei, brain MR imaging and spectroscopy: A review
With the increasing availability of ultra-high field MRI systems, studying non-proton nuclei (X-
nuclei), such as 23 Na and 31 P has received great interest. X-nuclei are able to provide …
nuclei), such as 23 Na and 31 P has received great interest. X-nuclei are able to provide …
Self-decoupled radiofrequency coils for magnetic resonance imaging
Arrays of radiofrequency coils are widely used in magnetic resonance imaging to achieve
high signal-to-noise ratios and flexible volume coverage, to accelerate scans using parallel …
high signal-to-noise ratios and flexible volume coverage, to accelerate scans using parallel …
Kerker effect in ultrahigh-field magnetic resonance imaging
Ultrahigh-field (UHF) magnetic resonance imaging (MRI) systems are getting a lot of
attention as they ensure high intrinsic signal-to-noise ratio resulting in higher spatial and …
attention as they ensure high intrinsic signal-to-noise ratio resulting in higher spatial and …
A review of parallel transmit arrays for ultra-high field MR imaging
Parallel transmission (pTX) techniques are required to tackle a number of challenges, eg,
the inhomogeneous distribution of the transmit field and elevated specific absorption rate …
the inhomogeneous distribution of the transmit field and elevated specific absorption rate …
Metamaterial combining electric-and magnetic-dipole-based configurations for unique dual-band signal enhancement in ultrahigh-field magnetic resonance imaging
Magnetic resonance imaging and spectroscopy (MRI and MRS) are both widely used
techniques in medical diagnostics and research. One of the major thrusts in recent years has …
techniques in medical diagnostics and research. One of the major thrusts in recent years has …
High-Q metasurface signal isolator for 1.5 T surface coil magnetic resonance imaging on the go
Q Ren, Y Lang, Y Jia, X **ao, Y Liu, X Kong, R **… - Optics …, 2024 - opg.optica.org
The combination of surface coils and metamaterials remarkably enhance magnetic
resonance imaging (MRI) performance for significant local staging flexibility. However, due …
resonance imaging (MRI) performance for significant local staging flexibility. However, due …
Radiofrequency coils for 7 Tesla MRI
O Kraff, HH Quick - Topics in Magnetic Resonance Imaging, 2019 - journals.lww.com
Radiofrequency (RF) coils are an essential part of the magnetic resonance (MR) system. To
exploit the inherently higher signal-to-noise ratio at ultrahigh magnetic fields (UHF) …
exploit the inherently higher signal-to-noise ratio at ultrahigh magnetic fields (UHF) …
Analysis of high impedance coils both in transmission and reception regimes
MSM Mollaei, CC Van Leeuwen… - IEEE …, 2020 - ieeexplore.ieee.org
Theory of a high impedance coil (HIC)-a cable loop antenna with a modified shield-is
comprehensively discussed for MRI application in both transmitting and receiving regimes …
comprehensively discussed for MRI application in both transmitting and receiving regimes …
Water-tunable highly sub-wavelength spiral resonator for magnetic field enhancement of MRI coils at 1.5 T
In magnetic resonance imaging (MRI), several studies have demonstrated that the
metamaterial-based structures can effectively improve the sensitivity, and thus the signal-to …
metamaterial-based structures can effectively improve the sensitivity, and thus the signal-to …