Report of the AAPM Task Group No. 105: Issues associated with clinical implementation of Monte Carlo‐based photon and electron external beam treatment planning

IJ Chetty, B Curran, JE Cygler, JJ DeMarco… - Medical …, 2007 - Wiley Online Library
The Monte Carlo (MC) method has been shown through many research studies to calculate
accurate dose distributions for clinical radiotherapy, particularly in heterogeneous patient …

Dose calculations for external photon beams in radiotherapy

A Ahnesjö, MM Aspradakis - Physics in Medicine & Biology, 1999 - iopscience.iop.org
Dose calculation methods for photon beams are reviewed in the context of radiation therapy
treatment planning. Following introductory summaries on photon beam characteristics and …

Report of AAPM Task Group 155: megavoltage photon beam dosimetry in small fields and non‐equilibrium conditions

IJ Das, P Francescon, JM Moran, A Ahnesjö… - Medical …, 2021 - Wiley Online Library
Small‐field dosimetry used in advance treatment technologies poses challenges due to loss
of lateral charged particle equilibrium (LCPE), occlusion of the primary photon source, and …

Small fields: nonequilibrium radiation dosimetry

IJ Das, GX Ding, A Ahnesjö - Medical physics, 2008 - Wiley Online Library
Advances in radiation treatment with beamlet‐based intensity modulation, image‐guided
radiation therapy, and stereotactic radiosurgery (including specialized equipments like …

Monte Carlo modelling of external radiotherapy photon beams

F Verhaegen, J Seuntjens - Physics in medicine & biology, 2003 - iopscience.iop.org
An essential requirement for successful radiation therapy is that the discrepancies between
dose distributions calculated at the treatment planning stage and those delivered to the …

A virtual photon energy fluence model for Monte Carlo dose calculation

M Fippel, F Haryanto, O Dohm, F Nüsslin… - Medical …, 2003 - Wiley Online Library
The presented virtual energy fluence (VEF) model of the patient‐independent part of the
medical linear accelerator heads, consists of two Gaussian‐shaped photon sources and one …

A CT‐based Monte Carlo simulation tool for dosimetry planning and analysis

JJ DeMarco, TD Solberg, JB Smathers - Medical physics, 1998 - Wiley Online Library
The Los Alamos code mcnp4a (M_onte C_arlo N_‐P_article version 4A) is currently used to
simulate a variety of problems ranging from nuclear reactor analysis to boron neutron …

Multi‐institution validation of a new high spatial resolution diode array for SRS and SBRT plan pretreatment quality assurance

MS Rose, L Tirpak, K Van Casteren, J Zack… - Medical …, 2020 - Wiley Online Library
Purpose The SRS MapCHECK®, a recently developed patient‐specific quality assurance
(PSQA) tool for end‐to‐end testing of stereotactic radiosurgery (SRS) and stereotactic body …

Verification of monitor unit calculations for non‐IMRT clinical radiotherapy: report of AAPM Task Group 114

RL Stern, R Heaton, MW Fraser… - Medical …, 2011 - Wiley Online Library
The requirement of an independent verification of the monitor units (MU) or time calculated
to deliver the prescribed dose to a patient has been a mainstay of radiation oncology quality …

Absolute dose calculations for Monte Carlo simulations of radiotherapy beams

IA Popescu, CP Shaw, SF Zavgorodni… - Physics in Medicine & …, 2005 - iopscience.iop.org
Monte Carlo (MC) simulations have traditionally been used for single field relative
comparisons with experimental data or commercial treatment planning systems (TPS) …