Current procedures and practices on grid code compliance verification of renewable power generation
A Etxegarai, P Eguia, E Torres, G Buigues… - … and Sustainable Energy …, 2017 - Elsevier
Generation assets applying for grid connection must comply with certain grid code
requirements. Grid code compliance verification shall include revision of documentation …
requirements. Grid code compliance verification shall include revision of documentation …
Technical challenges for the optimum penetration of grid-connected photovoltaic systems: Spain as a case study
This research reviews the technical requirements of grid-connected photovoltaic power
plants to increase their competitiveness and efficiently integrate into the grid to satisfy future …
plants to increase their competitiveness and efficiently integrate into the grid to satisfy future …
A combined control strategy of a DFIG based on a sensorless power control through modified phase-locked loop and fuzzy logic controllers
This paper presents a study on a sensorless decoupled PQ control for a doubly fed induction
generator (DFIG)-based wind energy conversion system (WECS) with intelligent controllers …
generator (DFIG)-based wind energy conversion system (WECS) with intelligent controllers …
Testing low voltage ride through capabilities of solar inverters
JEG Carrasco, JM Tena, D Ugena… - Electric Power Systems …, 2013 - Elsevier
The increase in the rated power of PV inverters has brought with it new requirements, such
as Low Voltage Ride Through and reactive power compensation. Field tests in PV plants are …
as Low Voltage Ride Through and reactive power compensation. Field tests in PV plants are …
Benchmarking of voltage sag generators
The increased penetration of renewable energy systems, like photovoltaic and wind power
systems, rises the concern about the power quality and stability of the utility grid. Some …
systems, rises the concern about the power quality and stability of the utility grid. Some …
Grid emulator for small scale distributed energy generation laboratory
This paper presents the design of a grid emulator dedicated to test small scale distributed
energy generation. laboratory The proposed emulator aims to test its performances under …
energy generation. laboratory The proposed emulator aims to test its performances under …
3‐Phase 4‐wire matrix converter‐based voltage sag/swell generator to test low‐voltage ride through in wind energy conversion systems
The high penetration of energy from wind energy conversion systems (WECSs) can have a
significant influence on the stability, power quality and reliability of power systems. Therefore …
significant influence on the stability, power quality and reliability of power systems. Therefore …
Matrix converter based Voltage Sag Generator to test LVRT capability in renewable energy systems
The increased penetration of renewable energy systems (RESs) rises the concern about the
stability and power quality of the utility grid. Therefore, some rather strict grid requirements …
stability and power quality of the utility grid. Therefore, some rather strict grid requirements …
Fault transient response of generic Type 3 wind turbine models: Limitations and extension of the validation methodology
Generic wind turbine (WT) models have amply demonstrated their capabilities for power
system stability studies. These models, developed by the IEC and the WECC, can adapt …
system stability studies. These models, developed by the IEC and the WECC, can adapt …
[PDF][PDF] Influence of LVRT Test Equipment Characteristics on the Dynamic Performance of a Power Generation Unit
N Essl, H Renner - International Conference & Exhibition on …, 2015 - graz.elsevierpure.com
Decentralized power plants have to stay connected to the grid during grid disturbances. Only
under certain conditions they are allowed to trip. The capability of power generation units …
under certain conditions they are allowed to trip. The capability of power generation units …