Modeling and simulation of a PI controlled shunt active power filter for power quality enhancement based on PQ theory

AA Imam, R Sreerama Kumar, YA Al-Turki - Electronics, 2020 - mdpi.com
The design of reliable power filters that mitigate current and voltage harmonics to meet the
power quality requirements of the utility grid is a major requirement of present-day power …

Comparison of control strategies for shunt active power filters in three-phase four-wire systems

MIM Montero, ER Cadaval… - IEEE transactions on …, 2007 - ieeexplore.ieee.org
Strategies for extracting the three-phase reference currents for shunt active power filters are
compared, evaluating their performance under different source and load conditions with the …

Application of a repetitive controller for a three-phase active power filter

A Garcia-Cerrada, O Pinzon-Ardila… - … on Power Electronics, 2007 - ieeexplore.ieee.org
This paper presents the detailed design, analysis, and application of the controller for a
shunt active power filter based on a pulsewidth modulation dc-to-ac voltage source …

A filter less improved control scheme for active/reactive energy management in fuel cell integrated grid system with harmonic reduction ability

ST Meraj, NZ Yahaya, K Hasan, MSH Lipu… - Applied Energy, 2022 - Elsevier
Fuel-cell integrated electrical grid systems are considered the future of energy generation
since it is highly energy-efficient and environmentally friendly. However, they are still in the …

Least mean squares and recursive least squares algorithms for total harmonic distortion reduction using shunt active power filter control

R Martinek, J Rzidky, R Jaros, P Bilik, M Ladrova - Energies, 2019 - mdpi.com
This paper deals with the use of least mean squares (LMS, NLMS) and recursive least
squares (RLS) algorithms for total harmonic distortion (THD) reduction using shunt active …

Harmonic and reactive power compensation with shunt active power filter under non-ideal mains voltage

M Kale, E Özdemir - Electric Power Systems Research, 2005 - Elsevier
This paper presents a new control algorithm for an active power filter (APF) to compensate
harmonic and reactive power of a 3-phase thyristor bridge rectifier under non-ideal mains …

Control of a 3-phase 4-leg active power filter under non-ideal mains voltage condition

M Ucar, E Ozdemir - Electric Power Systems Research, 2008 - Elsevier
In this paper, instantaneous reactive power theory (IRP), also known as p–q theory based a
new control algorithm is proposed for 3-phase 4-wire and 4-leg shunt active power filter …

Improvement of power quality by using hybrid fuzzy controlled based IPQC at various load conditions

G Satyanarayana, KNV Prasad… - … on Energy Efficient …, 2013 - ieeexplore.ieee.org
Dissimilar traditionalistic passive type harmonic power filters, modern active type harmonic
power filters have the favorable multiple functions: harmonic filtering, dam**, reactive …

Harmonics attenuation and power factor correction of a more electric aircraft power grid using active power filter

J Chen, X Zhang, C Wen - IEEE Transactions on Industrial …, 2016 - ieeexplore.ieee.org
In this paper, a novel active power filter (APF), which utilizes a highly reliable and efficient
dual-buck inversion topology, is designed and integrated to a more electric aircraft (MEA) …

pq Theory power components calculations

JL Afonso, MJS Freitas… - 2003 IEEE International …, 2003 - ieeexplore.ieee.org
The" generalized theory of the instantaneous reactive power in three-phase circuits",
proposed by Akagi et al., and also known as the pq theory, is an interesting tool to apply to …