Magnetic resonance thermometry and its biological applications–Physical principles and practical considerations

H Odéen, DL Parker - Progress in nuclear magnetic resonance …, 2019 - Elsevier
Most parameters that influence the magnetic resonance imaging (MRI) signal experience a
temperature dependence. The fact that MRI can be used for non-invasive measurements of …

MR techniques for guiding high‐intensity focused ultrasound (HIFU) treatments

K Kuroda - Journal of Magnetic Resonance Imaging, 2018 - Wiley Online Library
To make full use of the ability of magnetic resonance (MR) to guide high‐intensity focused
ultrasound (HIFU) treatment, effort has been made to improve techniques for thermometry …

Whole knee joint T1 values measured in vivo at 3T by combined 3D ultrashort echo time cones actual flip angle and variable flip angle methods

YJ Ma, W Zhao, L Wan, T Guo… - Magnetic resonance …, 2019 - Wiley Online Library
Purpose To measure T1 relaxations for the major tissues in whole knee joints on a clinical
3T scanner. Methods The 3D UTE‐Cones actual flip angle imaging (AFI) method was used …

MRI monitoring of temperature and displacement for transcranial focus ultrasound applications

V Ozenne, C Constans, P Bour, MD Santin… - Neuroimage, 2020 - Elsevier
Background Transcranial focus ultrasound applications applied under MRI-guidance benefit
from unrivaled monitoring capabilities, allowing the recording of real-time anatomical …

[KSIĄŻKA][B] Theory and Applications of Heat Transfer in Humans, 2 Volume Set

D Shrivastava - 2018 - books.google.com
An authoritative guide to theory and applications of heat transfer in humans Theory and
Applications of Heat Transfer in Humans 2V Set offers a reference to the field of heating and …

Rotator cuff tendon assessment using magic‐angle insensitive 3D ultrashort echo time cones magnetization transfer (UTE‐Cones‐MT) imaging and modeling with …

Y Zhu, X Cheng, Y Ma, JH Wong, Y **e… - Journal of Magnetic …, 2018 - Wiley Online Library
Background Rotator cuff tendons (RCTs) are challenging to image due to the “magic angle
effect” and their short T2. Purpose To assess the degree of magic angle sensitivity of human …

Feasibility of using an inversion-recovery ultrashort echo time (UTE) sequence for quantification of glenoid bone loss

Y Ma, J West, A Nazaran, X Cheng, H Hoenecke, J Du… - Skeletal radiology, 2018 - Springer
Objective To utilize the 3D inversion recovery prepared ultrashort echo time with cones
readout (IR-UTE-Cones) MRI technique for direct imaging of lamellar bone with comparison …

Recent technological advancements in thermometry

D Kokuryo, E Kumamoto, K Kuroda - Advanced Drug Delivery Reviews, 2020 - Elsevier
Thermometry is the key factor for achieving successful thermal therapy. Although invasive
thermometry with a probe has been used for more than four decades, this method can only …

Finite element analysis of bone mechanical properties using MRI-derived bound and pore water concentration maps

T Ketsiri, S Uppuganti, KD Harkins… - Computer methods in …, 2023 - Taylor & Francis
Ultrashort echo time (UTE) MRI techniques can be used to image the concentration of water
in bones. Particularly, quantitative MRI imaging of collagen-bound water concentration (C …

T1 measurement of bound water in cortical bone using 3D adiabatic inversion recovery ultrashort echo time (3D IR‐UTE) Cones imaging

T Guo, Y Ma, S Jerban, H Jang, W Zhao… - Magnetic resonance …, 2020 - Wiley Online Library
Purpose We describe the measurement of bound water T1 () of cortical bone in vitro and in
vivo with a 3D adiabatic inversion recovery ultrashort echo time (IR‐UTE) Cones sequence …