Effect of different parameters on the performance of FRP anchors in combination with EBR-FRP strengthening systems: A review
The use of fiber-reinforced polymer (FRP) composites using externally bonded
reinforcement (EBR) installation technique is an alternative to conventional retrofitting …
reinforcement (EBR) installation technique is an alternative to conventional retrofitting …
[HTML][HTML] Numerical simulation of the influence of bond strength degradation on the behavior of reinforced concrete beam-column joints externally strengthened with …
Limited information is known about the effects of bond strength degradation during
installation on the bond's quality and performance between fiber-reinforced polymer (FRP) …
installation on the bond's quality and performance between fiber-reinforced polymer (FRP) …
The shear strength of existing non-seismic RC beam-column joints strengthened with CFRP Sheets: Numerical and analytical study
A key part of RC structure seismic performance is the effective distribution of earthquake
forces across all resistance elements through reinforced concrete (RC) beam-column (BC) …
forces across all resistance elements through reinforced concrete (RC) beam-column (BC) …
[HTML][HTML] Cyclic behavior of alkali-silica reaction-damaged reinforced concrete beam-column joints strengthened with FRP composites
RZ Al-Rousan - Case Studies in Construction Materials, 2022 - Elsevier
The research investigates the effect of using external fiber-reinforced polymer (FRP)–
composites to strengthen the alkali-silica reaction (ASR)-damaged reinforced concrete (RC) …
composites to strengthen the alkali-silica reaction (ASR)-damaged reinforced concrete (RC) …
[HTML][HTML] Evaluation of bond strength of helically ribbed CFRP bar connections as mechanical anchorage schemes
SW Yoo, J Shin, JF Choo - Case Studies in Construction Materials, 2024 - Elsevier
In spite of their outstanding properties, FRP reinforcing bars still face a series of drawbacks
that should be addressed to widen their applications. For example, straight FRP bars must …
that should be addressed to widen their applications. For example, straight FRP bars must …
[HTML][HTML] Rehabilitation of damaged RC exterior beam-column joint using various configurations of CFRP laminates subjected to cyclic excitations
G Palanisamy, V Kumarasamy - Matéria (Rio de Janeiro), 2023 - SciELO Brasil
In this research, an investigational study on the use of CFRP laminates with 4 types of
configurations (Series-A: laminated with confinement wrap, Series-B: single flat & L wrap …
configurations (Series-A: laminated with confinement wrap, Series-B: single flat & L wrap …
NLFEA of sulfate-damaged circular CFT steel columns confined with CFRP composites and subjected to axial and cyclic lateral loads
It is rather costly and difficult to experimentally evaluate the performance of concrete-filled
tubular (CFT) circular steel columns exposed to combined axial and cyclic lateral loads. This …
tubular (CFT) circular steel columns exposed to combined axial and cyclic lateral loads. This …
[HTML][HTML] Hysteretic behavior of composite beam-reinforced concrete column frame
X Lu, Z Zhu, K Wang, D Yang, Y Zhu, C Dai - Results in Engineering, 2024 - Elsevier
Based on experimental data of composite beam-reinforced concrete column frames, a
corresponding finite element (FE) numerical model was established using the OpenSees. By …
corresponding finite element (FE) numerical model was established using the OpenSees. By …
Experimental investigation of EBROG and bore-epoxy anchorage methods used for interior RC beam-column joints strengthened with CFRP sheets
K Cetin, TY Altiok, A Demir - Structures, 2024 - Elsevier
In severe earthquakes, the energy dissipation and ductility capacities of the structures
depend on the performance of the beam-column joints where the load transfer is performed …
depend on the performance of the beam-column joints where the load transfer is performed …
[HTML][HTML] Fatigue response of RC beam strengthened by BFRP laminate
P Manibalan, S Kesavan, G Abirami… - Case Studies in …, 2023 - Elsevier
Strengthening RC structures become more essential due to its deterioration, updating in
new design codes, lack of quality control, and changes in the use of the structure. The …
new design codes, lack of quality control, and changes in the use of the structure. The …