Turnitin
降AI改写
早检测系统
早降重系统
Turnitin-UK版
万方检测-期刊版
维普编辑部版
Grammarly检测
Paperpass检测
checkpass检测
PaperYY检测
On real-time detection of line sags in overhead power grids using an iot-based monitoring system: theoretical basis, system implementation, and long-term field …
JA Jiang, HC Chiu, YC Yang, JC Wang… - IEEE Internet of …, 2022 - ieeexplore.ieee.org
For overhead power grids, unexpected serious line sagging of extra-high voltage
transmission lines would easily lead to major blackouts. Different direct and indirect sag …
transmission lines would easily lead to major blackouts. Different direct and indirect sag …
Влияние режимных и климатических факторов на потери энергии при нестационарных тепловых режимах линий электропередачи
АЯ Бигун, ОА Сидоров, ДС Осипов… - Динамика систем …, 2017 - cyberleninka.ru
В современной электроэнергетической сети возрастают потери электрической
энергии. Потери связаны с повышением потребления. Существующие модели оценки …
энергии. Потери связаны с повышением потребления. Существующие модели оценки …
Overhead power line heating dynamic processes calculation based on the heat transfer quadratic model
SS Girshin, VN Gorjunov, AY Bigun… - 2016 Dynamics of …, 2016 - ieeexplore.ieee.org
A new approach to the non-stationary thermal processes calculation in the overhead power
lines was developed. Using the developed approach we can solve the current problem of …
lines was developed. Using the developed approach we can solve the current problem of …
Methodology for transmission line capacity assessement based on PMU data
This paper reflects the authors' experience in conductor thermal part (temperature) and
mechanical part (sag and clearance) estimation in real Latvian PS conditions using IEEE …
mechanical part (sag and clearance) estimation in real Latvian PS conditions using IEEE …
Mode and climatic factors effect on energy losses in transient heat modes of transmission lines
AY Bigun, OA Sidorov, DS Osipov… - Journal of Physics …, 2018 - iopscience.iop.org
Electrical energy losses increase in modern grids. The losses are connected with an
increase in consumption. Existing models of electric power losses estimation considering …
increase in consumption. Existing models of electric power losses estimation considering …
Fault Location in Power Distribution Grids using Phasor Measurement Units
MM Al-Khabbaz - 2018 - search.proquest.com
This thesis proposes utilization of an impedance-based model in power distribution systems
equipped with phasor measurement units (PMUs) for fault location purpose. The model has …
equipped with phasor measurement units (PMUs) for fault location purpose. The model has …
[PDF][PDF] Assessment of climatic factors influence on the time to reach maximum wire temperature of overhead power lines
AAY Bigun, SS Girshin, VN Goryunov… - Przeglad …, 2020 - pe.org.pl
With the growth of electricity consumption, there is an increase in electrical energy losses
and a decrease in the capacity of the lines. Also, the limited capacity affects the efficiency of …
and a decrease in the capacity of the lines. Also, the limited capacity affects the efficiency of …
University impact on power supply economy, reliability and sustainability enhancement decreasing climate changes
Research in prior scientific areas carried out by Riga Technical university (RTU), in general,
and the Institute of Power Engineering as part of the University is of vital importance not only …
and the Institute of Power Engineering as part of the University is of vital importance not only …
РАСПРЕДЕЛЕНИЕ ТЕМПЕРАТУР ПО СЕЧЕНИЮ В ИЗОЛИРОВАННОМ ПРОВОДЕ ПРИ НЕСТАЦИОНАРНОМ ТЕПЛОВОМ РЕЖИМЕ ИЗОЛИРОВАННЫХ …
НВ Маликова, АМ Мельникова… - … и энергосбережение в …, 2022 - elibrary.ru
В работе представлен обзор существующих математических моделей, позволяющих
учитывать фактическую температуру токоведущих частей, обусловленную режимными …
учитывать фактическую температуру токоведущих частей, обусловленную режимными …
Overhead line weak point mechanical analysis based on Markov chain method
In this work, a concept for overhead power line weak point analysis based on the calculation
of minimal clearance to ground is presented. Line temperature should be known before …
of minimal clearance to ground is presented. Line temperature should be known before …