Dosimetry for FLASH radiotherapy: a review of tools and the role of radioluminescence and Cherenkov emission
While spatial dose conformity delivered to a target volume has been pushed to its practical
limits with advanced treatment planning and delivery, investigations in novel temporal dose …
limits with advanced treatment planning and delivery, investigations in novel temporal dose …
Review of plastic and liquid scintillation dosimetry for photon, electron, and proton therapy
While scintillation dosimetry has been around for decades, the need for a dosimeter tailored
to the reality of modern radiation therapy—in particular a real-time, water-equivalent, energy …
to the reality of modern radiation therapy—in particular a real-time, water-equivalent, energy …
Spectral method for the correction of the Cerenkov light effect in plastic scintillation detectors: a comparison study of calibration procedures and validation in Cerenkov …
Purpose: The purposes of this work were:(1) To determine if a spectral method can
accurately correct the Cerenkov light effect in plastic scintillation detectors (PSDs) for …
accurately correct the Cerenkov light effect in plastic scintillation detectors (PSDs) for …
Projection imaging of photon beams using Čerenkov-excited fluorescence
Full 3D beam profiling and quality assurance (QA) of therapeutic megavoltage linear
accelerator (LINAC) x-ray photon beams is not routinely performed due to the slow point-by …
accelerator (LINAC) x-ray photon beams is not routinely performed due to the slow point-by …
Characterization of a new scintillation imaging system for proton pencil beam dose rate measurements
The goal of this work was to create a technique that could measure all possible spatial and
temporal delivery rates used in pencil-beam scanning (PBS) proton therapy. The proposed …
temporal delivery rates used in pencil-beam scanning (PBS) proton therapy. The proposed …
Quality assurance in proton beam therapy using a plastic scintillator and a commercially available digital camera
Purpose In this article, we evaluate a plastic scintillation detector system for quality
assurance in proton therapy using a BC‐408 plastic scintillator, a commercial camera, and a …
assurance in proton therapy using a BC‐408 plastic scintillator, a commercial camera, and a …
Novel, full 3D scintillation dosimetry using a static plenoptic camera
Purpose: Patient‐specific quality assurance (QA) of dynamic radiotherapy delivery would
gain from being performed using a 3D dosimeter. However, 3D dosimeters, such as gels …
gain from being performed using a 3D dosimeter. However, 3D dosimeters, such as gels …
Quenching correction for volumetric scintillation dosimetry of proton beams
D Robertson, D Mirkovic, N Sahoo… - Physics in Medicine & …, 2012 - iopscience.iop.org
Volumetric scintillation dosimetry has the potential to provide fast, high-resolution, three-
dimensional radiation dosimetry. However, scintillators exhibit a nonlinear response at the …
dimensional radiation dosimetry. However, scintillators exhibit a nonlinear response at the …
Optical artefact characterization and correction in volumetric scintillation dosimetry
The goals of this study were (1) to characterize the optical artefacts affecting measurement
accuracy in a volumetric liquid scintillator detector, and (2) to develop methods to correct for …
accuracy in a volumetric liquid scintillator detector, and (2) to develop methods to correct for …
Verification of proton range, position, and intensity in IMPT with a 3D liquid scintillator detector system
L Archambault, F Poenisch, N Sahoo… - Medical …, 2012 - Wiley Online Library
Purpose: Intensity‐modulated proton therapy (IMPT) using spot scanned proton beams
relies on the delivery of a large number of beamlets to shape the dose distribution in a highly …
relies on the delivery of a large number of beamlets to shape the dose distribution in a highly …