X-ray and gamma imaging with Medipix and Timepix detectors in medical research

S Procz, C Avila, J Fey, G Roque, M Schuetz… - Radiation …, 2019 - Elsevier
The innovations brought by Medipix and Timepix detector readout chips have improved
medical imaging. Firstly, the small pixel size enables a very high spatial resolution in …

Investigation of CdTe, GaAs, Se and Si as sensor materials for mammography

S Procz, G Roque, C Avila, J Racedo… - IEEE transactions on …, 2020 - ieeexplore.ieee.org
Despite the benefits of mammography investigations, some studies have shown that X-ray
exposure from the mammography screening itself can statistically cause breast cancer in a …

Study of Contrast-to-Noise Ratio performance of a Medipix3RX CdTe detector for low dose mammography imaging

G Roque, C Avila, ML Pérez-Lara, L Mendoza… - Nuclear Instruments and …, 2021 - Elsevier
This study compares detector performance through measurements of Contrast-to-Noise
Ratio (CNR) of images obtained by a standard commercial X-ray mammography setup …

Medipix3 CT for material sciences

S Procz, KA Wartig, A Fauler, A Zwerger… - Journal of …, 2013 - iopscience.iop.org
Innovative detector systems for non-destructive material analysis and for medical diagnosis
are an important development to improve the performance and the quality of examination …

A hybrid pixel detector ASIC with energy binning for real-time, spectroscopic dose measurements

W Wong - 2012 - diva-portal.org
Hybrid pixel detectors have been demonstrated to provide excellent quality detection of
ionising photon radiation, particularly in X-ray imaging. Recently, there has been interest in …

Applications of the Medipix3-CT in combination with iterative reconstruction techniques

F Fischer, S Procz, A Fauler… - Journal of …, 2016 - iopscience.iop.org
The pixelated semiconductor detectors of the Medipix family with their photon-counting
abilities offer the possibility of high quality X-ray radiography as well as computed …

Investigation of the radiation dose in computed micro tomography using the Medipix3 semiconductor detector in combination with an iterative reconstruction algorithm

F Fischer, S Procz, A Fauler… - 2014 IEEE Nuclear …, 2014 - ieeexplore.ieee.org
Due to the acquisition of up to two thousand projections, the radiation dose during computed
tomography scans is severely higher, compared to planar radiographic imaging. Especially …

[CITATION][C] Mikrocomputertomographie mit photonenprozessierenden Pixeldetektoren und iterativer Rekonstruktionsmethodik–Bildeigenschaften bei reduzierter …

F Fischer - 2020 - Dissertation, Universität Freiburg …

[CITATION][C] Eingangsdatenspezifische Artefaktreduktion für algebraische Rekonstruktionsverfahren in der Computertomographie am Beispiel von …

VAE Heusinger - Dissertation, Universität Freiburg …

[CITATION][C] Charakterisierung von CdTe-Schichten für die Anwendung als Röntgendetektor

A Vogt - Dissertation, Albert-Ludwigs …