Grid-supportive loads—a new approach to increasing renewable energy in power systems

H Jain, B Mather, AK Jain… - IEEE Transactions on …, 2022 - ieeexplore.ieee.org
This paper demonstrates the potential of inverter-based loads to support grid reliability
during power system transients thereby enabling reliable integration of renewable energy in …

Innovative load shedding scheme to restore synchronous generator-based microgrids during FIDVR

R Bekhradian, M Sanaye-Pasand… - IEEE Transactions on …, 2022 - ieeexplore.ieee.org
Fault induced voltage recovery (FIDVR) phenomenon may occur in microgrids (Gs) and
distribution systems due to the induction motors (IMs) behavior after system voltage sags …

Load shedding strategy using online voltage estimation process for mitigating fault-induced delayed voltage recovery in smart networks

M Ghotbi-Maleki, RM Chabanloo, H Javadi - Electric Power Systems …, 2023 - Elsevier
Load shedding can be used to compensate for some imbalance between the generated and
requested powers in order to deal with destructive effects of fault-induced delayed voltage …

A Data-driven Trajectory Approach for Dynamic VAr Support in Renewable Rich Power Grid

A Alshareef, R Shah, N Mithulananthan, U Akram… - Ieee …, 2024 - ieeexplore.ieee.org
Short-term voltage stability (STVS) of power grids could be jeopardized due to the nonlinear
dynamic characteristics of loads such as induction motors (IMs) and the retirement of …

Modeling of rectifier-controlled induction motor drive load in transient stability simulation tools

Y Liu, V Vittal - IEEE Transactions on Power Systems, 2018 - ieeexplore.ieee.org
This paper proposes a novel comprehensive model of a rectifier-controlled induction motor
drive for use in positive-sequence transient stability simulation (PSTSS) programs. The …

Comparison of load shedding methods for mitigating FIDVR

M Ghotbi-Maleki, RM Chabanloo… - … on Protection and …, 2023 - ieeexplore.ieee.org
Fault-induced delayed voltage recovery (FIDVR) occurs after a fault in a network with high
penetration of induction motor (IM) loads. Load shedding (LS) is one of the appropriate …

Open-source high-fidelity aggregate composite load models of emerging load behaviors for large-sale analysis

Y Liu, S Kundu, Q Huang, M Ghosal, J Zhang… - 2020 - osti.gov
The goal of this project is to accurately model the dynamic loads for power system planning
and operation and to address the challenges inherent in such modeling. Existing load …

A power converter based real-time air-conditioner motor emulator

S Wang, H Li, J Wang, Y Ma, F Wang… - 2020 IEEE Applied …, 2020 - ieeexplore.ieee.org
The residential air-conditioner (A/C) is one of the most widespread load types for a
household in the US, and it is reported that the malfunction of A/C load influences the …

Hybrid emt-ts simulation strategies to study high bandwidth mmc-based hvdc systems

Y Liu, MA Elizondo, S Debnath, J Sun… - 2020 IEEE Power & …, 2020 - ieeexplore.ieee.org
Modular multilevel converters (MMCs) are widely used in the design of modern high-voltage
direct current (HVdc) transmission system. High-fidelity dynamic models of MMCs-based …

[PDF][PDF] Design of Central Unit for Voltage Estimation-based Load Shedding Methods to Deal with FIDVR

M Ghotbi-Maleki, R Mohammadi… - AUT Journal of …, 2024 - researchgate.net
Fault-induced delayed voltage recovery (FIDVR) occurs after fault in the network with high
penetration of induction motor (IM) loads. Load shedding (LS) is one of the appropriate …