Turnitin
降AI改写
早检测系统
早降重系统
Turnitin-UK版
万方检测-期刊版
维普编辑部版
Grammarly检测
Paperpass检测
checkpass检测
PaperYY检测
Grid-supportive loads—a new approach to increasing renewable energy in power systems
This paper demonstrates the potential of inverter-based loads to support grid reliability
during power system transients thereby enabling reliable integration of renewable energy in …
during power system transients thereby enabling reliable integration of renewable energy in …
Innovative load shedding scheme to restore synchronous generator-based microgrids during FIDVR
Fault induced voltage recovery (FIDVR) phenomenon may occur in microgrids (Gs) and
distribution systems due to the induction motors (IMs) behavior after system voltage sags …
distribution systems due to the induction motors (IMs) behavior after system voltage sags …
Load shedding strategy using online voltage estimation process for mitigating fault-induced delayed voltage recovery in smart networks
M Ghotbi-Maleki, RM Chabanloo, H Javadi - Electric Power Systems …, 2023 - Elsevier
Load shedding can be used to compensate for some imbalance between the generated and
requested powers in order to deal with destructive effects of fault-induced delayed voltage …
requested powers in order to deal with destructive effects of fault-induced delayed voltage …
A Data-driven Trajectory Approach for Dynamic VAr Support in Renewable Rich Power Grid
Short-term voltage stability (STVS) of power grids could be jeopardized due to the nonlinear
dynamic characteristics of loads such as induction motors (IMs) and the retirement of …
dynamic characteristics of loads such as induction motors (IMs) and the retirement of …
Modeling of rectifier-controlled induction motor drive load in transient stability simulation tools
Y Liu, V Vittal - IEEE Transactions on Power Systems, 2018 - ieeexplore.ieee.org
This paper proposes a novel comprehensive model of a rectifier-controlled induction motor
drive for use in positive-sequence transient stability simulation (PSTSS) programs. The …
drive for use in positive-sequence transient stability simulation (PSTSS) programs. The …
Comparison of load shedding methods for mitigating FIDVR
M Ghotbi-Maleki, RM Chabanloo… - … on Protection and …, 2023 - ieeexplore.ieee.org
Fault-induced delayed voltage recovery (FIDVR) occurs after a fault in a network with high
penetration of induction motor (IM) loads. Load shedding (LS) is one of the appropriate …
penetration of induction motor (IM) loads. Load shedding (LS) is one of the appropriate …
Open-source high-fidelity aggregate composite load models of emerging load behaviors for large-sale analysis
The goal of this project is to accurately model the dynamic loads for power system planning
and operation and to address the challenges inherent in such modeling. Existing load …
and operation and to address the challenges inherent in such modeling. Existing load …
A power converter based real-time air-conditioner motor emulator
The residential air-conditioner (A/C) is one of the most widespread load types for a
household in the US, and it is reported that the malfunction of A/C load influences the …
household in the US, and it is reported that the malfunction of A/C load influences the …
Hybrid emt-ts simulation strategies to study high bandwidth mmc-based hvdc systems
Modular multilevel converters (MMCs) are widely used in the design of modern high-voltage
direct current (HVdc) transmission system. High-fidelity dynamic models of MMCs-based …
direct current (HVdc) transmission system. High-fidelity dynamic models of MMCs-based …
[PDF][PDF] Design of Central Unit for Voltage Estimation-based Load Shedding Methods to Deal with FIDVR
Fault-induced delayed voltage recovery (FIDVR) occurs after fault in the network with high
penetration of induction motor (IM) loads. Load shedding (LS) is one of the appropriate …
penetration of induction motor (IM) loads. Load shedding (LS) is one of the appropriate …