Energy dissipation systems for seismic applications: current practice and recent developments

MD Symans, FA Charney, AS Whittaker… - Journal of structural …, 2008 - ascelibrary.org
This paper presents a summary of current practice and recent developments in the
application of passive energy dissipation systems for seismic protection of structures. The …

Review on passive energy dissipation devices and techniques of installation for high rise building structures

KYM Almajhali - Structures, 2023 - Elsevier
Retrofitting and building design using passive energy dissipation Devices have been shown
to be effective techniques for decreasing seismic risk. Numerous complementary energy …

Structural control: past, present, and future

GW Housner, LA Bergman, TK Caughey… - Journal of …, 1997 - ascelibrary.org
This tutorial/survey paper:(1) provides a concise point of departure for researchers and
practitioners alike wishing to assess the current state of the art in the control and monitoring …

Experimental characterization on cyclic stability behavior of a high-dam** viscoelastic damper

Z He, F Shi, Z Lin, C Zhang, Y Zhou, F Zhao - Construction and Building …, 2023 - Elsevier
This study explores the mechanical behavior of a viscoelastic damper (VED) under
monotonic and cyclic loading, focusing on the cyclic stability of VEDs' mechanical properties …

[BOEK][B] Handbook of structural engineering

WF Chen, EM Lui - 2005 - taylorfrancis.com
Continuing the best-selling tradition of the Handbook of Structural Engineering, this second
edition is a comprehensive reference to the broad spectrum of structural engineering …

The role of viscoelastic dam** on retrofitting seismic performance of asymmetric reinforced concrete structures

Z Alam, C Zhang, B Samali - Earthquake Engineering and Engineering …, 2020 - Springer
The primary purpose of this research is to improve the seismic response of a complex
asymmetric tall structure using viscoelastic (VE) dampers. Asymmetric structures have …

Experimental assessment of retrofitting RC moment resisting frames with ADAS and TADAS yielding dampers

M TahamouliRoudsari, MB Eslamimanesh, AR Entezari… - Structures, 2018 - Elsevier
Due to the lack of sufficient concrete strength or change in design codes, some RC
structures are in need of retrofitting. Retrofitting and reevaluating a building is only possible …

Use of viscoelastic dampers in reducing wind-and earthquake-induced motion of building structures

B Samali, KCS Kwok - Engineering Structures, 1995 - Elsevier
Viscoelastic (VE) dampers have been successfully incorporated in a number of tall buildings
as a viable energy dissipating system to suppress wind-and earthquake-induced motion of …

Modeling of viscoelastic dampers for structural applications

KL Shen, TT Soong - Journal of Engineering Mechanics, 1995 - ascelibrary.org
This paper presents an analytical model for predicting the hysteretic behavior of viscoelastic
dampers based on the Boltzmann's superposition principle and the method of reduced …

Analytical and experimental investigation of a motion amplified rotational friction damper

AA Kulaksizoglu, C Yalcin, C Yilmaz - Engineering Structures, 2023 - Elsevier
This article introduces a novel rotational friction damper to enhance energy dissipation
capacity of structures. The proposed damper contributes to force and energy dissipation …