Fitness for service assessment of a pressure vessel subjected to fire damage in a refinery unit

R Bakhtiari, S Zangeneh, MB Fotouh… - Engineering Failure …, 2017 - Elsevier
The fire-damaged pressure vessel reactor, evaluated in this study, was a cylindrical vessel
with design conditions of 460 psig (3.17 MPa) at 413° C. The fitness for service (FFS) of the …

Uncertainty in damage assessment and remaining life prediction of engineering materials used in petrochemical industry

AK Ray, N Roy, M Matwa, A Davuluri… - Petroleum & …, 2014 - eprints.nmlindia.org
In this paper creep damage assessment of about 11 years' service exposed HP-40 grade of
steel used in hydrogen reformer of a petrochemical industry has been carried out in terms of …

Creep damage and remaining life assessment of service exposed engineering materials used in petrochemical industry

P Kumar, A Ray - Journal of Metallurgy and Materials Science, 2015 - indianjournals.com
In this paper creep damage assessment of 55 years service exposed Catalytic Cold
Cracking (CCU) reactor vessel and Feed Processing Unit (FPU) distillation column materials …