The surgical management of glaucoma: A review

R Lim - Clinical & Experimental Ophthalmology, 2022 - Wiley Online Library
After a long period of little change, glaucoma surgery has experienced a dramatic rise in the
number of possible procedures in the last two decades. Glaucoma filtering surgeries with …

XEN Gel Implant: a new surgical approach in glaucoma

A Chaudhary, L Salinas, J Guidotti… - Expert Review of …, 2018 - Taylor & Francis
Introduction: Glaucoma is a leading cause of blindness worldwide. Intraocular pressure
(IOP) lowering is the only effective treatment strategy. Traditional glaucoma surgeries are …

Safety profile of minimally invasive glaucoma surgery

K Vinod, SJ Gedde - Current opinion in ophthalmology, 2021 - journals.lww.com
Trabecular meshwork/Schlemm's canal-based procedures are generally among the safest
MIGS, with mostly self-limited and nonvision-threatening complications. Subconjunctival gel …

Identifying the predictors of needling after XEN gel implant

N Midha, HL Rao, A Mermoud, K Mansouri - Eye, 2019 - nature.com
Purpose To identify factors associated with probability of needling after XEN implant.
Methods Analysis of data from prospective case series of patients with standalone XEN …

XEN implant for glaucoma treatment: a review of the literature

A Chatzara, I Chronopoulou… - Seminars in …, 2019 - Taylor & Francis
Purpose: The purpose of this review is to summarize current knowledge on XEN implant for
the treatment of glaucoma. Methods: A comprehensive literature review has been performed …

Anterior Segment Optical Coherence Tomography for Cases of High Intraocular Pressure Following XEN Implant for Glaucoma

F Tatti, F Lixi, G Demarinis, P Napoli… - Journal of …, 2024 - journals.lww.com
Purpose: To evaluate the application of the anterior segment optical coherence tomography
(AS-OCT) imaging in studying the relationship between a low flow rate through the XEN63 …

An innovation in glaucoma surgery: XEN45 gel stent implantation

SA Ozal, O Kaplaner, BB Basar, H Guclu… - Arquivos Brasileiros de …, 2017 - SciELO Brasil
Purpose: To report follow-up data for patients who underwent XEN45 gel stent implantation,
a new method of minimally invasive glaucoma surgery. Methods: Fifteen eyes in fifteen …

Needling with 5-fluorouracil (5-FU) after XEN gel stent implantation: 6-month outcomes

TS Arnljots, R Kasina, VJN Bykov… - Journal of …, 2018 - journals.lww.com
Purpose: The purpose of this study was to evaluate frequency, safety, and efficacy of
needling in patients that underwent XEN Gel Stent implantation. Methods: Retrospective …

Early postoperative intraocular pressure is associated with better pressure control after XEN implantation

CA Cutolo, M Iester, A Bagnis, C Bonzano… - Journal of …, 2020 - journals.lww.com
Purpose: To identify the variables associated with the success of the XEN procedure.
Patients and Methods: This was part of a prospective, uncontrolled, consecutive case series …

Recanalization of Xen45 gel stent implant occlusion using 10− 0 nylon suture in refractory glaucoma: a case report

Y Zhang, H **ang, Y Zhang, L Tang - BMC ophthalmology, 2023 - Springer
Abstract Background Xen Gel Stent implant is a new minimally invasive surgical treatment
for glaucoma that has been proven effectiveness and safety profile. However, it may also …