Digital twins and automation of care in the intensive care unit
Healthcare is under increasing demand pressure as societies age and expectations rise,
multiplied by increasing incidence of chronic diseases and decreasing available funding …
multiplied by increasing incidence of chronic diseases and decreasing available funding …
Model based care in the ICU: A review of potential combined cardio-pulmonary models
Positive end-expiratory pressure results in a sustained positive intrathoracic pressure, which
exerts pressure on intrathoracic vessels, resulting in cardiopulmonary interactions. This …
exerts pressure on intrathoracic vessels, resulting in cardiopulmonary interactions. This …
Virtual patient framework for the testing of mechanical ventilation airway pressure and flow settings protocol
Abstract Background and Objective Model-based and personalised decision support
systems are emerging to guide mechanical ventilation (MV) treatment for respiratory failure …
systems are emerging to guide mechanical ventilation (MV) treatment for respiratory failure …
[HTML][HTML] CAREDAQ: Data acquisition device for mechanical ventilation waveform monitoring
Mechanical ventilation (MV) provides respiratory support for critically ill patients in the
intensive care unit (ICU). Waveform data output by the ventilator provides valuable …
intensive care unit (ICU). Waveform data output by the ventilator provides valuable …
Structural performance and damage prediction using a novel digital cloning technique
This paper presents a novel, mechanics-based framework to create digital twins for
earthquake-affected pinched structures, like reinforced concrete framed buildings. It uses …
earthquake-affected pinched structures, like reinforced concrete framed buildings. It uses …
Low-cost structured light imaging of regional volume changes for use in assessing mechanical ventilation
Background Optimal setting of mechanical ventilators is critical for improving outcomes.
Accurate, predictive lung mechanics models are effective in optimizing MV settings, but only …
Accurate, predictive lung mechanics models are effective in optimizing MV settings, but only …
Protocol conception for safe selection of mechanical ventilation settings for respiratory failure Patients
Abstract Background and Objective Mechanical ventilation is the primary form of care
provided to respiratory failure patients. Limited guidelines and conflicting results from major …
provided to respiratory failure patients. Limited guidelines and conflicting results from major …
Modelling patient specific cardiopulmonary interactions
Mechanical ventilation is well known for having detrimental effects on the cardiovascular
system, particularly when using high positive end-expiratory pressure. High positive end …
system, particularly when using high positive end-expiratory pressure. High positive end …
[HTML][HTML] Patient-ventilator asynchrony classification in mechanically ventilated patients: Model-based or machine learning method?
Background and objective Patient-ventilator asynchrony (PVA) is associated with poor
clinical outcomes and remains under-monitored. Automated PVA detection would enable …
clinical outcomes and remains under-monitored. Automated PVA detection would enable …
Automated evaluation of typical patient–ventilator asynchronies based on lung hysteretic responses
Background Patient–ventilator asynchrony is common during mechanical ventilation (MV) in
intensive care unit (ICU), leading to worse MV care outcome. Identification of asynchrony is …
intensive care unit (ICU), leading to worse MV care outcome. Identification of asynchrony is …