Turnitin
降AI改写
早检测系统
早降重系统
Turnitin-UK版
万方检测-期刊版
维普编辑部版
Grammarly检测
Paperpass检测
checkpass检测
PaperYY检测
Assessment of dislocation density in asymmetrically cyclic loaded non-conventional stainless steel using X-ray diffraction profile analysis
Asymmetric stress-controlled fatigue ie, ratcheting behaviour of a non-conventional stainless
steel X12CrMnNiN17-7-5 has been investigated with varying mean stresses, stress …
steel X12CrMnNiN17-7-5 has been investigated with varying mean stresses, stress …
Low temperature tensile deformation and acoustic emission signal characteristics of AISI 304LN stainless steel
This investigation examines low temperature tensile deformation behavior of AISI 304LN
stainless steel along with synergistic analysis of acoustic emission signals. The tensile tests …
stainless steel along with synergistic analysis of acoustic emission signals. The tensile tests …
Crack tip fields at crack initiation and growth under monotonic and large amplitude cyclic loading: experimental and FE analyses
In this paper, experiment and FE analyses are performed to investigate crack tip deformation
and stress fields under monotonic and large amplitude cyclic loading. Fracture tests using C …
and stress fields under monotonic and large amplitude cyclic loading. Fracture tests using C …
Fracture toughness of high-alloy austenitic-martensitic TRIP steels after Q&P processing
R Eckner, L Krüger, C Ullrich, M Wendler… - International Journal of …, 2019 - Springer
The recently developed austenitic-martensitic TRIP cast steel Fe–14Cr–3Ni–3Mn–0.4 Si–
0.11 N–0.15 C was subjected to different Quenching & Partitioning (Q&P) treatments in order …
0.11 N–0.15 C was subjected to different Quenching & Partitioning (Q&P) treatments in order …
Tensile deformation temperature impact on microstructure and mechanical properties of AISI 316LN austenitic stainless steel
Y **ong, T He, Y Lu, F Ren, AA Volinsky… - Journal of Materials …, 2018 - Springer
Uniaxial tensile tests were conducted on AISI 316LN austenitic stainless steel from− 40 to
300° C at a rate of 0.5 mm/min. Microstructure and mechanical properties of the deformed …
300° C at a rate of 0.5 mm/min. Microstructure and mechanical properties of the deformed …
Pitting corrosion failure of an AISI stainless steel pointer rod
In this study, failure analysis of a thermostatic mixing valve pointer rod made of AISI 304
stainless steel was performed. Visual examination, followed by an in-depth microstructural …
stainless steel was performed. Visual examination, followed by an in-depth microstructural …
On the comparative assessment of ratcheting-induced dislocation density in 42CrMo4 steel by X-ray diffraction profile analysis and hardness measurement
The phenomenon of ratcheting occurs under the influence of non-zero mean stress during
cyclic loading; it singificantly reduces the low cycle fatigue life of engineering structures. The …
cyclic loading; it singificantly reduces the low cycle fatigue life of engineering structures. The …
On the characteristic features of dislocations during ratcheting–creep interaction
The present investigation systematically represents for the first time the density and role of
characteristic dislocations in controlling ratcheting and ratcheting–creep behavior of A356 Al …
characteristic dislocations in controlling ratcheting and ratcheting–creep behavior of A356 Al …
Ratcheting behavior of a non-conventional stainless steel and associated microstructural variations
Ratcheting fatigue behavior of a non-conventional stainless steel X12CrMnNiN17-7-5 has
been investigated with varying combinations of mean stress (σ m) and stress amplitude (σ a) …
been investigated with varying combinations of mean stress (σ m) and stress amplitude (σ a) …
Determination of Fracture Toughness Characteristics of Small-Size Chevron-Notched Specimens
Y Deryugin - Contact and Fracture Mechanics, 2018 - books.google.com
A new method is proposed to determine fracture toughness of structural materials according
to the test data of non-standard small-size chevron-notched specimens. Dur-ing the tests …
to the test data of non-standard small-size chevron-notched specimens. Dur-ing the tests …