Ultrasound open platforms for next-generation imaging technique development

E Boni, CH Alfred, S Freear, JA Jensen… - IEEE transactions on …, 2018 - ieeexplore.ieee.org
Open platform (OP) ultrasound systems are aimed primarily at the research community. They
have been at the forefront of the development of synthetic aperture, plane wave, shear wave …

Pulsing and Detection Strategies for Contrast-Enhanced Ultrasound: A Narrative Review

SR Bisht, VV Trivedi, R Bhardwaj… - IEEE Open Journal …, 2023 - ieeexplore.ieee.org
Contrast-enhanced imaging has grown significantly in the past two decades. Technology
has evolved from imaging based on linear principles to elaborate pulsing and microbubble …

[HTML][HTML] Characterisation of liposome-loaded microbubble populations for subharmonic imaging

JR McLaughlan, S Harput, RH Abou-Saleh… - Ultrasound in Medicine …, 2017 - Elsevier
Therapeutic microbubbles could make an important contribution to the diagnosis and
treatment of cancer. Acoustic characterisation was performed on microfluidic generated …

[HTML][HTML] Ultrasonic propagation in highly attenuating insulation materials

DA Hutchins, RL Watson, LAJ Davis, L Akanji… - Sensors, 2020 - mdpi.com
Experiments have been performed to demonstrate that ultrasound in the 100–400 kHz
frequency range can be used to propagate signals through various types of industrial …

Subharmonic, non-linear fundamental and ultraharmonic imaging of microbubble contrast at high frequencies

V Daeichin, JG Bosch, A Needles, FS Foster… - Ultrasound in medicine …, 2015 - Elsevier
There is increasing use of ultrasound contrast agent in high-frequency ultrasound imaging.
However, conventional contrast detection methods perform poorly at high frequencies. We …

A new dynamic complex baseband pulse compression method for chirp-coded excitation in medical ultrasound imaging

J Kang, Y Kim, W Lee, Y Yoo - IEEE transactions on ultrasonics …, 2017 - ieeexplore.ieee.org
Chirp-coded excitation can increase the signal-to-noise ratio (SNR) without degrading the
axial resolution. Effective pulse compression (PC) is important to maintain the axial …

HIFU drive system miniaturization using harmonic reduced pulsewidth modulation

C Adams, TM Carpenter, D Cowell… - IEEE transactions on …, 2018 - ieeexplore.ieee.org
Switched excitation has the potential to improve on the cost, efficiency, and size of the linear
amplifier circuitry currently used in high-intensity focused ultrasound (HIFU) systems …

New performance metrics for ultrasound pulse compression systems

S Harput, J McLaughlan, DMJ Cowell… - 2014 IEEE …, 2014 - ieeexplore.ieee.org
In medical ultrasound, B-mode images are log-compressed and displayed with a grayscale
map, typically on a 40–60 dB dynamic range. The image formation process is the same for …