Towards estimating arterial diameter using bioimpedance spectroscopy: a computational simulation and tissue phantom analysis

Y Yu, G Anand, A Lowe, H Zhang, A Kalra - Sensors, 2022 - mdpi.com
This paper improves the accuracy of quantification in the arterial diameter-dependent
impedance variance by altering the electrode configuration. The finite element analysis was …

Analysis of the radial pulse wave and its clinical applications: a survey

J Yang, L Yang, W Liu, S Du, L Xu, G He, A Avolio… - IEEE …, 2021 - ieeexplore.ieee.org
The arterial pulse wave is a physiological signal which can reflect the function of the human
cardiovascular system. Owing to the measurement being convenient and safe, radial pulse …

Derivation of bioimpedance model data utilizing a compact analyzer and two capacitive electrodes: a forearm example

J Ojarand, E Priidel, M Min - IEEE Transactions on Biomedical …, 2022 - ieeexplore.ieee.org
The paper investigates the impacts of the selected electrical equivalent circuit model,
measurement setup, and surrounding environment on the trustworthiness of electrical …

[HTML][HTML] Radial artery pulse wave estimation by compressed sensing measurements of wrist bio-impedance

J Kromka, J Saliga, O Kovac, L De Vito, F Picariello… - Measurement, 2023 - Elsevier
In this paper, a Compressive Sampling (CS) based measurement method of the Bio-
Impedance (Bio-Z) variation at the wrist, due to the blood flow inside of radial artery, is …

FPGA-based processor for continual capacitive-coupling impedance spectroscopy and circuit parameter estimation

A Tsukahara, T Yamaguchi, Y Tanaka, A Ueno - Sensors, 2022 - mdpi.com
In principle, the recently proposed capacitive-coupling impedance spectroscopy (CIS) has
the capability to acquire frequency spectra of complex electrical impedance sequentially on …

Wearable Optical E-Tattoo for Deep Neck Hemodynamic Monitoring

P Tan, S Tamma, S Bhattacharya… - 2022 IEEE/ACM …, 2022 - ieeexplore.ieee.org
Noninvasive detection of blood oxygen abnormalities in arteries and veins is crucial for
determining sepsis, shock, and metabolic demand but is still unattainable. In this work, we …

[PDF][PDF] A novel CS-based measurement method for radial artery pulse wave estimation

J Kromka, J Saliga, O Kovac, L De Vito… - 25th IMEKO TC-4 …, 2022 - imeko.org
This paper presents a compressive sampling (CS) based measurement method for
estimation of radial artery pulse wave from bio-impedance (Bio-Z) variation. The …

Multiwavelength Photoplethysmography and Bioimpedance Multimodal Signal Analysis above the Radial Artery on the Wrist

JP McMurray, S Idah-Oze, KL Branan… - 2023 IEEE …, 2023 - ieeexplore.ieee.org
As wearable devices continue to advance, the implementation of additional sensors and
device health monitoring capabilities has become integral to their development. To explore …

Analysis, Simulation, and Development of a Low-Cost Fully Active-Electrode Bioimpedance Measurement Module

C Dimas, V Alimisis, I Georgakopoulos, N Voudoukis… - Technologies, 2021 - mdpi.com
A low-cost 1 kHz–400 kHz operating frequency fully-active electrode bioimpedance
measurement module, based on Howland current source, is presented in this paper. It …

A Tunable System for High Frequency Bioimpedance Plethysmography

DH Tebbs - 2023 - scholarsarchive.byu.edu
Bioimpedance measurements are useful for determining a variety of biological conditions.
By accounting for small impedance variations due to the arterial pulse, the effect of the blood …