[PDF][PDF] Utilization of electric prosumer flexibility incentivized by spot and balancing markets

M Lösch - 2022 - scholar.archive.org
The use of energy flexibility to balance electricity demand and supply is becoming
increasingly important due to the growing share of fluctuating energy sources. Electric …

Determinants of low energy performance in a multi-chiller system serving an educational premise

WT Ho, FW Yu - International Journal of Refrigeration, 2020 - Elsevier
This study analyses an association between operating variables and low energy
performance in terms of the coefficient of performance (COP) of a chiller system in daily …

Optimizing chiller switch-on time interval for chiller power consumption saving via big data analytics and machine learning framework

YC Tsai, CF Chien, YJ Chen… - 2019 Joint International …, 2019 - ieeexplore.ieee.org
In semiconductor manufacturing, the chiller water system requires huge energy
consumption, especially in the countries which have high temperature and humidity climate …

[PDF][PDF] Methodology for the preparation and selection of black box mathematical models for the energy simulation of screw type chillers

Y Díaz-Torres, M Santana-Justiz… - Ingeniería …, 2020 - redalyc.org
This article proposes a methodology for the construction and simultaneous evaluation of
black box models for screw type water chillers. The estimation method used was …

Metodología para la confección y selección de modelos matemáticos de caja negra para la simulación energética de enfriadoras tipo tornillo

Y Díaz-Torres, M Santana-Justiz… - Ingeniería …, 2020 - scielo.sld.cu
This article proposes a methodology for the construction and simultaneous evaluation of
black box models for screw type water chillers. The estimation method used was …

Coefficient of Performance (COP) evaluation of electric water-cooled chiller during partial/full load operation at PUTRAJAYA plant 1

LH Mazlan - 2020 - utpedia.utp.edu.my
Air-conditioning and refrigeration system are the most energy consuming as the energy are
needed to cool the system. COP stands for Coefficient of Performance and it is indicating the …

[PDF][PDF] Thermophysical Properties and Performance Evaluation of a Mechanical Vapor Compression Cycle with Next Generation Refrigerants

ACU Perera - 2019 - catalog.lib.kyushu-u.ac.jp
Refrigeration (HVAC&R) industry has a major impact on the energy use of nations as well as
the contribution towards climatic issues such as Global Warming. The global demand for the …

[CITAS][C] Analisa Performansi Penggantian Starter Motor Dengan Tipe Variabel Speed Konvensional Pada Mesin Chiller

I Retnanto - Jurnal Cahaya Mandalika ISSN 2721-4796 …, 2024 - ojs.cahayamandalika.com
Pemakaian energi listrik untuk sistem pendingin mencapai 47%-65% dari total keseluruhan
energi listrik yang dipergunakan di gedung. Oleh karenanya, agar dapat mengurangi …