A perspective of multi‐reflecting TOF MS
AN Verenchikov, VV Makarov… - Mass Spectrometry …, 2024 - Wiley Online Library
Time‐of‐flight mass spectrometry (TOF MS) excels in rapid and high‐sensitivity analysis,
making it a cornerstone of analytical chemistry. But as sample complexity explodes in omics …
making it a cornerstone of analytical chemistry. But as sample complexity explodes in omics …
[HTML][HTML] Increased beam energy as a pathway towards a highly selective and high-flux MR-ToF mass separator
Many experiments at radioactive ion beam (RIB) facilities suffer from isobaric contamination,
ie unwanted ions of similar mass. During the last decade, Multi-Reflection Time-of-Flight …
ie unwanted ions of similar mass. During the last decade, Multi-Reflection Time-of-Flight …
First Glimpse of the Shell Closure below from Masses of Neutron-Rich Cadmium Isotopes and Isomers
We probe the N= 82 nuclear shell closure by mass measurements of neutron-rich cadmium
isotopes with the ISOLTRAP spectrometer at ISOLDE-CERN. The new mass of Cd 132 offers …
isotopes with the ISOLTRAP spectrometer at ISOLDE-CERN. The new mass of Cd 132 offers …
Commissioning and performance of TITAN's Multiple-Reflection Time-of-Flight Mass-Spectrometer and isobar separator
TRIUMF's Ion Trap for Atomic and Nuclear science (TITAN) has specialized in fast Penning
Trap mass spectrometry of very short-lived radioactive isotopes. The facility has been …
Trap mass spectrometry of very short-lived radioactive isotopes. The facility has been …
Mass Measurements of Neutron-Deficient Yb Isotopes and Nuclear Structure at the Extreme Proton-Rich Side of the Shell
High-accuracy mass measurements of neutron-deficient Yb isotopes have been performed
at TRIUMF using TITAN's multiple-reflection time-of-flight mass spectrometer (MR-TOF-MS) …
at TRIUMF using TITAN's multiple-reflection time-of-flight mass spectrometer (MR-TOF-MS) …
The new MRTOF mass spectrograph following the ZeroDegree spectrometer at RIKEN's RIBF facility
M Rosenbusch, M Wada, S Chen, A Takamine… - Nuclear Instruments and …, 2023 - Elsevier
A newly assembled multi-reflection time-of-flight mass spectrograph (MRTOF-MS) at
RIKEN's RIBF facility became operational for the first time in spring 2020; further …
RIKEN's RIBF facility became operational for the first time in spring 2020; further …
Precision Mass Measurements of : Nuclear Collectivity Towards the Island of Inversion
The neutron-rich isotopes Cr 58–63 were produced for the first time at the ISOLDE facility
and their masses were measured with the ISOLTRAP spectrometer. The new values are up …
and their masses were measured with the ISOLTRAP spectrometer. The new values are up …
Isomeric Excitation Energy for from Mass Spectrometry Reveals Constant Trend Next to Doubly Magic
The excitation energy of the 1/2− isomer in In 99 at N= 50 is measured to be 671 (37) keV
and the mass uncertainty of the 9/2+ ground state is significantly reduced using the …
and the mass uncertainty of the 9/2+ ground state is significantly reduced using the …
Crowd control of ions in the Astral analyzer
Abstract Space charge effects are the Achilles' heel of all high‐resolution ion optical devices.
In time‐of‐flight mass analyzers, these may manifest as reduction of resolving power, mass …
In time‐of‐flight mass analyzers, these may manifest as reduction of resolving power, mass …
A multi-reflection time-of-flight mass spectrometer for the offline ion source of the PUMA experiment
M Schlaich, J Fischer, P Fischer, C Klink… - International Journal of …, 2024 - Elsevier
Abstract The antiProton Unstable Matter Annihilation experiment (PUMA) at CERN aims at
investigating the nucleon composition in the matter density tail of radioactive as well as …
investigating the nucleon composition in the matter density tail of radioactive as well as …