Experimental behavior of fire-exposed reinforced concrete slabs without and with FRP retrofitting

V Van Cao, HB Vo, LH Dinh, D Van Doan - Journal of Building Engineering, 2022 - Elsevier
In this study, experiments were conducted on nine reinforced concrete slabs which were
divided into three groups, namely S0, S45, and S75. Group S0 included one slab which was …

Performance of steel bar lap splices at the base of seismic resistant reinforced concrete columns retrofitted with FRPs—3D finite element analysis

E Anagnostou, T Rousakis - Fibers, 2022 - mdpi.com
This paper examines analytically the design criteria for the composite retrofit of reinforced
concrete (RC) columns with a short lap splice length of steel rebars inside the critical region …

Experimental study of seismic behavior of high-strength RC columns strengthened with CFRP subjected to cyclic loading

J Wang, J Yang, L Cheng - Journal of Structural Engineering, 2019 - ascelibrary.org
Eight high-strength RC columns confined by carbon fiber–reinforced polymer (CFRP) sheets
and two control specimens are tested under cyclic lateral load and constant axial load. The …

Seismic behavior of preloaded rectangular RC columns strengthened with precambered steel plates under high axial load ratios

L Wang, RKL Su, B Cheng, LZ Li, L Wan… - Engineering Structures, 2017 - Elsevier
In the past 20 years, numerous tests have been conducted to demonstrate the effectiveness
of additional fiber reinforced polymers (FRPs) or steel jacketing in the seismic retrofit of …

Experimental investigation on the seismic performance of GFRP-wrapped thin-walled steel tube confined RC columns

Z Cai, D Wang, ST Smith, Z Wang - Engineering Structures, 2016 - Elsevier
In order to eliminate buckling in thin-walled steel tube confined reinforced concrete (RC)
columns, the external fiber-reinforced polymer (FRP) composite wraps may be applied. This …

[HTML][HTML] Seismic retrofitting of damaged RC columns with lap-spliced bars using FRP sheets

E Anagnostou, TC Rousakis, AI Karabinis - Composites Part B: Engineering, 2019 - Elsevier
In many cases, existing reinforced concrete (RC) columns have been designed according to
old seismic recommendations and present inefficient seismic behavior. Moreover, they …

Experimental study of jacket height and reinforcement effects on seismic retrofitting of concrete columns

A Zaiter, TL Lau - Structures, 2021 - Elsevier
This study evaluates the jacket height and reinforcement effects on reinforced concrete (RC)
square columns retrofitted with normal concrete. Five one-third scale columns with non …

Experimental and Analytical Study on Postfire Reinforced Concrete Beams Retrofitted with CFRP in Flexure and Shear

VN Nguyen, V Van Cao - Civil Engineering Journal, 2023 - civilejournal.org
In this study, experiments were performed on carbon fiber reinforced polymer (CFRP)
retrofitted postfire reinforced concrete (RC) beams, followed by theoretical analyzes …

Rehabilitation and strengthening techniques for reinforced concrete columns

AJ Naji, HM Al-Jelawy, SA Saadoon… - Journal of Physics …, 2021 - iopscience.iop.org
Reinforced concrete (RC) columns are the primary load-bearing structural components in
the building which makes them most likely vulnerable to deterioration. Capacity deterioration …

Seismic performance of predamaged RC columns strengthened with HPFL and BSP under combined loadings

H Huang, M Huang, W Zhang, M Guo, S Pospisil - Engineering Structures, 2020 - Elsevier
This paper presents an experimental investigation of the seismic behavior of coupling
predamaged reinforced concrete (RC) columns strengthened with high-performance …