Turnitin
降AI改写
早检测系统
早降重系统
Turnitin-UK版
万方检测-期刊版
维普编辑部版
Grammarly检测
Paperpass检测
checkpass检测
PaperYY检测
A review of optimization approaches for controlling water-cooled central cooling systems
Buildings consume a large amount of energy across all sectors of society, and a large
proportion of building energy is used by HVAC systems to provide a comfortable and healthy …
proportion of building energy is used by HVAC systems to provide a comfortable and healthy …
Robust optimization based optimal chiller loading under cooling demand uncertainty
Optimization of electrical power consumption in multi-chiller system leads to save more
energy in building or industrial locations. Also, this optimization problem is one of the most …
energy in building or industrial locations. Also, this optimization problem is one of the most …
A new approach for optimal chiller loading using an improved imperialist competitive algorithm
J Cai, H Yang, T Lai, K Xu - Energy and Buildings, 2023 - Elsevier
A new optimization algorithm based on an improved imperialist competitive algorithm (ICA-
DE) is proposed to reduce the energy consumption of a multi-chiller system. The …
DE) is proposed to reduce the energy consumption of a multi-chiller system. The …
Design and optimization of autonomous solar-wind-reverse osmosis desalination systems coupling battery and hydrogen energy storage by an improved bee …
A Maleki - Desalination, 2018 - Elsevier
Most of the global population are not connected to the electrical grid and one third of these
people have no access to potable water sources at the same time. Grid independent hybrid …
people have no access to potable water sources at the same time. Grid independent hybrid …
A multi-strategy improved sparrow search algorithm of large-scale refrigeration system: Optimal loading distribution of chillers
Z Li, J Guo, X Gao, X Yang, YL He - Applied Energy, 2023 - Elsevier
At present, the energy consumption of the parallel chillers system accounts for about 60% of
the whole energy consumption of central air conditioning system and 25–40% of the total …
the whole energy consumption of central air conditioning system and 25–40% of the total …
Energy optimization methodology of multi-chiller plant in commercial buildings
This study investigates the potential energy savings in commercial buildings through
optimized operation of a multi-chiller plant. The cooling load contributes 45–60% of total …
optimized operation of a multi-chiller plant. The cooling load contributes 45–60% of total …
Medium spatiotemporal characteristics based global optimization method for energy efficiency trade-off issue in variable flow rate HVAC system
J Wang, T Zhao - Applied Thermal Engineering, 2024 - Elsevier
During the optimization and control processes of variable flow rate heating, ventilation, and
air conditioning (HVAC) systems, the medium temporal and spatial characteristics often …
air conditioning (HVAC) systems, the medium temporal and spatial characteristics often …
Design and operation optimization of multi-chiller plants based on energy performance simulation
Buildings consume about 20% of the total primary energy use in China. It is critical to
enhancing building energy efficiency for sustainable development. The heating, ventilation …
enhancing building energy efficiency for sustainable development. The heating, ventilation …
A method for energy consumption optimization of air conditioning systems based on load prediction and energy flexibility
W Li, G Gong, Z Ren, Q Ouyang, P Peng, L Chun… - Energy, 2022 - Elsevier
A new method for heating ventilation and air conditioning (HVAC) energy consumption
optimization based on load prediction and energy flexibility is proposed. First, the energy …
optimization based on load prediction and energy flexibility is proposed. First, the energy …
Distributed chiller loading via collaborative neurodynamic optimization with heterogeneous neural networks
In the operation planning of heating, ventilation, and air conditioning systems, optimal chiller
loading assigns cooling loads to chillers with minimized power consumption. In this article, a …
loading assigns cooling loads to chillers with minimized power consumption. In this article, a …