Fragility fractures of the pelvis

PM Rommens, D Wagner, A Hofmann - JBJS reviews, 2017 - journals.lww.com
JBJS Reviews JBJS Journal Case Connector Reviews JBJS.org Surgical Techniques Open
Access JOPA Log in Subscribe to journalSubscribe Get new issue alertsGet alerts Secondary …

Treatment of osteochondral lesions of the talus: a critical analysis review

TJ Dekker, PK Dekker, DM Tainter, ME Easley… - JBJS …, 2017 - journals.lww.com
Abstract➢ Osteochondral lesions of the talus remain difficult pathological entities to treat and
require the utilization of a combination of conventional radiographs, computed tomographic …

Comparison of proximal humeral bone stresses between stemless, short stem, and standard stem length: a finite element analysis

N Razfar, JM Reeves, DG Langohr, R Willing… - Journal of shoulder and …, 2016 - Elsevier
Background The stem lengths of humeral components used in shoulder arthroplasty vary;
however, the literature on these devices is limited. This finite element study investigates the …

A general multi-objective topology optimization methodology developed for customized design of pelvic prostheses

T Iqbal, L Wang, D Li, E Dong, H Fan, J Fu… - Medical engineering & …, 2019 - Elsevier
In this study, a multi-objective topology optimization method has been formulated and
carried out for various resection types, with minimization of a weighted sum of the …

Sacral bone mass distribution assessed by averaged three-dimensional CT models: implications for pathogenesis and treatment of fragility fractures of the sacrum

D Wagner, L Kamer, T Sawaguchi, RG Richards… - JBJS, 2016 - journals.lww.com
Background: Fragility fractures of the sacrum are increasing in prevalence due to
osteoporosis and epidemiological changes and are challenging in their treatment. They …

Topology optimization of 3D-printed structurally porous cage for acetabular reinforcement in total hip arthroplasty

A Moussa, S Rahman, M Xu, M Tanzer… - Journal of the mechanical …, 2020 - Elsevier
Aseptic loosening and mechanical failure of acetabular reinforcement components are
among the main causes of their reduced service life. Current acetabular implants typically …

Progressive instability of bilateral sacral fragility fractures in osteoporotic bone: a retrospective analysis of X-ray, CT, and MRI datasets from 78 cases

T Mendel, BW Ullrich, GO Hofmann, P Schenk… - European Journal of …, 2021 - Springer
Purpose The pathogenetic mechanism, progression, and instability in geriatric bilateral
fragility fractures of the sacrum (BFFSs) remain poorly understood. This study investigated …

Finite element analysis of a hemi-pelvis: the effect of inclusion of cartilage layer on acetabular stresses and strain

R Ghosh, B Pal, D Ghosh, S Gupta - Computer methods in …, 2015 - Taylor & Francis
An appropriate method of application of the hip-joint force and stress analysis of the pelvic
bone, in particular the acetabulum, is necessary to investigate the changes in load transfer …

The effect of boundary condition on the biomechanics of a human pelvic joint under an axial compressive load: a three-dimensional finite element model

Z Hao, C Wan, X Gao, T Ji - 2011 - asmedigitalcollection.asme.org
The finite element (FE) model of the pelvic joint is helpful for clinical diagnosis and treatment
of pelvic injuries. However, the effect of an FE model boundary condition on the …

Development of finite element model for customized prostheses design for patient with pelvic bone tumor

T Iqbal, L Shi, L Wang, Y Liu, D Li… - Proceedings of the …, 2017 - journals.sagepub.com
The aim of this study was to design a hemi-pelvic prosthesis for a patient affected by pelvic
sarcoma. To investigate the biomechanical functionality of the pelvis reconstructed with …