Experimental validation of a novel compact focusing scheme for future energy-frontier linear lepton colliders
GR White, R Ainsworth, T Akagi, J Alabau-Gonzalvo… - Physical review …, 2014 - APS
A novel scheme for the focusing of high-energy leptons in future linear colliders was
proposed in 2001 [P. Raimondi and A. Seryi, Phys. Rev. Lett. 86, 3779 (2001)]. This scheme …
proposed in 2001 [P. Raimondi and A. Seryi, Phys. Rev. Lett. 86, 3779 (2001)]. This scheme …
Noninvasive micrometer-scale particle-beam size measurement using optical diffraction radiation in the ultraviolet wavelength range
M Bergamaschi, A Aryshev, P Karataev, R Kieffer… - Physical Review …, 2020 - APS
We present recent achievements in the application of optical diffraction radiation (ODR) to
the measurement of the transverse beam size of a 1.3 GeV micrometer-size electron beam …
the measurement of the transverse beam size of a 1.3 GeV micrometer-size electron beam …
Design and performance of a high resolution, low latency stripline beam position monitor system
RJ Apsimon, DR Bett, N Blaskovic Kraljevic… - Physical Review Special …, 2015 - APS
A high-resolution, low-latency beam position monitor (BPM) system has been developed for
use in particle accelerators and beam lines that operate with trains of particle bunches with …
use in particle accelerators and beam lines that operate with trains of particle bunches with …
A nanometer beam size monitor for ATF2
T Suehara, M Oroku, T Yamanaka, H Yoda… - Nuclear Instruments and …, 2010 - Elsevier
We developed an electron beam size monitor for nanometer scaled beam sizes. It uses a
laser interference fringe for a scattering target with the electron beam. The target beam size …
laser interference fringe for a scattering target with the electron beam. The target beam size …
Design and operation of a prototype interaction point beam collision feedback system for the International Linear Collider
RJ Apsimon, DR Bett, N Blaskovic Kraljevic… - … Review Accelerators and …, 2018 - APS
A high-resolution, intratrain position feedback system has been developed to achieve and
maintain collisions at the proposed future electron-positron International Linear Collider …
maintain collisions at the proposed future electron-positron International Linear Collider …
High-resolution, low-latency, bunch-by-bunch feedback system for nanobeam stabilization
DR Bett, N Blaskovic Kraljevic, T Bromwich… - … Review Accelerators and …, 2022 - APS
We report the design, operation, and performance of a high-resolution, low-latency, bunch-
by-bunch feedback system for nanobeam stabilization. The system employs novel, ultralow …
by-bunch feedback system for nanobeam stabilization. The system employs novel, ultralow …
A sub-micron resolution, bunch-by-bunch beam trajectory feedback system and its application to reducing wakefield effects in single-pass beamlines
DR Bett, PN Burrows, C Perry… - Journal of …, 2021 - iopscience.iop.org
A high-precision intra-bunch-train beam orbit feedback correction system has been
developed and tested in the ATF2 beamline of the Accelerator Test Facility at the High …
developed and tested in the ATF2 beamline of the Accelerator Test Facility at the High …
Luminosity performance studies of the compact linear collider with intra-train feedback system at the interaction point
J Resta-Lopez, PN Burrows… - Journal of …, 2010 - iopscience.iop.org
To achieve the design luminosity at future linear colliders, control of beam stability at the sub-
nanometre level at the interaction point will be necessary. Any source of beam motion which …
nanometre level at the interaction point will be necessary. Any source of beam motion which …
Cavity BPM system tests for the ILC energy spectrometer
The main physics programme of the International Linear Collider (ILC) requires a
measurement of the beam energy at the interaction point with an accuracy of 10-4 or better …
measurement of the beam energy at the interaction point with an accuracy of 10-4 or better …
Cavity beam position monitor system for ATF2
ST Boogert, D McCormick, T Smith, A Heo, Y Honda… - 2011 - cds.cern.ch
Abstract The Accelerator Test Facility 2 (ATF2) in KEK, Japan, is a prototype scaled
demonstrator system for the final focus required for a future high energy lepton linear …