A New Lumped Parameter Modeling for Wind Farm Grounding Measurement Circuits Based on Clamp-on Ground Meters
AG Leal, AE Lazzaretti… - Journal of Control …, 2024 - Springer
Over the years, researchers have proposed models for analyzing and predicting the low-
frequency behavior of wind farm grounding systems. The lumped parameter modeling …
frequency behavior of wind farm grounding systems. The lumped parameter modeling …
Double Ground Fault Resistance
AI Mugu - 2023 Seminar on Fields, Waves, Photonics and …, 2023 - ieeexplore.ieee.org
In this paper we present a computation method of resistance between two electrodes buried
in the ground. Electrodes have different electric potentials, current flows through the ground …
in the ground. Electrodes have different electric potentials, current flows through the ground …
[PDF][PDF] Experimental study of induced voltage between two bare horizontal electrodes in ground
This paper investigates induced voltage between two identical finite horizontal electrodes in
same plan (horizontal and vertical). Various arrangements of horizontal electrodes were …
same plan (horizontal and vertical). Various arrangements of horizontal electrodes were …
A study of mutual coupling between vertical grounding electrodes
Y Fujita, A Ametani, K Nakamura… - … Engineering in Japan, 2014 - Wiley Online Library
This paper investigates the mutual grounding impedance between vertical grounding
electrodes based on field measurements and FDTD simulations. In the case of vertical …
electrodes based on field measurements and FDTD simulations. In the case of vertical …
Caracterização de arranjos de aterramento através de medições no domínio do tempo
CEF Caetano - 2019 - repositorio.ufmg.br
Nesta tese um conjunto de conceitos capaz de definir uma nova perspectiva para a
caracterização de arranjos de aterramento é desenvolvido, baseado na proposição de três …
caracterização de arranjos de aterramento é desenvolvido, baseado na proposição de três …
垂直接地電極間の相互誘導に関する研究
藤田悠太, 雨谷昭弘, 中村圭佑… - 電気学会論文誌 B (電力 …, 2012 - jstage.jst.go.jp
抄録 This paper investigates a mutual grounding impedance between vertical grounding
electrodes based on field measurements and FDTD simulations. In the case of vertical …
electrodes based on field measurements and FDTD simulations. In the case of vertical …
Numerical estimation of mutual grounding impedance between building structure and loop electrode buried around building base
T Kusuda, N Nagaoka, A Ametani… - 45th International …, 2010 - ieeexplore.ieee.org
An equivalent circuit of a grounding system for a building base with a loop electrode is
proposed in this paper. The loop electrode is buried around the building base for bypassing …
proposed in this paper. The loop electrode is buried around the building base for bypassing …
A Study on the Grounding Impedance Effects and Its Characteristics
MS Chang, KW Park, CH Kim - Proceedings of the KIEE …, 2007 - koreascience.kr
This paper presents the characteristics and effects of grounding resistor and impedance. In
grounding system, Grounding resistor is governed neutral currents and voltage. It seems …
grounding system, Grounding resistor is governed neutral currents and voltage. It seems …
접지 임피던스가 중성선 고조파 전류에 미치는 영향
김경철, 백승현, 이일무, 김종욱 - 조명· 전기설비학회논문지, 2004 - dbpia.co.kr
스위칭 모드 전원 공급 장치와 같은 비선형 부하의 증가로, 3 상 4 선식 배전계통을 채용하는
중성선에 많은 고조파 전류가 흐른다. 중성선은 접지 시스템과 연결되어 있기 때문에 접지 …
중성선에 많은 고조파 전류가 흐른다. 중성선은 접지 시스템과 연결되어 있기 때문에 접지 …