Cost-benefit analysis to assess seismic mitigation options in Mexican public school buildings
This study presents a methodology to perform a cost-benefit (C/B) analysis to assess
possible options such as retrofitting or reconstruction of structures focused on mitigation of …
possible options such as retrofitting or reconstruction of structures focused on mitigation of …
Full-scale tests of gapped-inclined bracing system: seismic retrofit for soft-story buildings
J Salmon, H Agha Beigi… - Journal of Structural …, 2019 - ascelibrary.org
This paper presents the results of full-scale experimental validations of the gapped-inclined
bracing (GIB) system, a novel structural device for the seismic retrofit of soft-story buildings …
bracing (GIB) system, a novel structural device for the seismic retrofit of soft-story buildings …
Reliability-Based Selection of Retrofit Works for Schools under Seismic Hazard
D De-Leon, AHS Ang, DA Guadarrama - Natural Hazards Review, 2023 - ascelibrary.org
A reliability-based procedure is proposed to assess and compare the economic
effectiveness of three retrofit alternatives for actual schools located in three zones with …
effectiveness of three retrofit alternatives for actual schools located in three zones with …
[PDF][PDF] Towards a resilient design and retrofit of schools in México
D De León, A Donaji - 17 th World Conference on Earthquake …, 2020 - wcee.nicee.org
The paper deals with the generation of practical recommendations for design and retrofit of
schools in Mexico on the basis of modern resiliency ideas and the application of well-known …
schools in Mexico on the basis of modern resiliency ideas and the application of well-known …
[PDF][PDF] The use of seismic risk maps in the development of seismic risk reduction programs
Map** seismic risk at the territorial scale is a key process in earthquake-prone countries
since it allows to understand the spatial distribution of risk and its quantification in economic …
since it allows to understand the spatial distribution of risk and its quantification in economic …
Application of three-dimensional modified inclined braces to control soft-story buildings
S Nodehi, SM Zahrai - Structural Engineering and Mechanics, An Int'l …, 2022 - dbpia.co.kr
Despite its disadvantages, soft story can reduce the damage to the upper floors by
concentrating drift in that specific story provided that large drifts are avoided. Gapped …
concentrating drift in that specific story provided that large drifts are avoided. Gapped …
Cost and reliability of retrofit alternatives for schools located on seismic zones
D De Leon-Escobedo… - Earthquakes and …, 2021 - koreascience.kr
A formulation based on structural reliability and cost effectiveness is proposed to provide
recommendations to select the best retrofit strategy for schools with reinforced concrete …
recommendations to select the best retrofit strategy for schools with reinforced concrete …
[PDF][PDF] Reparación de daños sísmicos en un edificio escolar con base en análisis riesgo/beneficio Retrofit of seismic damage on a school building based on risk …
DLE David - IngenIería InvestIgacIón y tecnología, 2024 - revistaingenieria.unam.mx
La generación de normas de reparación de daños sísmicos en estructuras escolares de
México vive apenas etapas tempranas. En el presente trabajo se presenta una formulación …
México vive apenas etapas tempranas. En el presente trabajo se presenta una formulación …
[BOEK][B] Full-Scale Testing and Improvements to the Design and Use of the Gapped-Inclined Bracing System
J Salmon - 2021 - search.proquest.com
The gapped-inclined bracing (GIB) system is an innovative retrofitting device that was
developed to improve the performance and prevent the collapse of reinforced concrete (RC) …
developed to improve the performance and prevent the collapse of reinforced concrete (RC) …
[PDF][PDF] The assessment of the seismic performance of the RC buildings having one or two soft-stories retrofitted with gapped inclined bracing
AA Shahsahebi, Z Waezi - … کنفرانس بينالمللي زلزلهشناسي و مهندسي زلزله, 2019 - iiees.ac.ir
Aghabeigi et al.(2015) introduced a new method called gapped inclined bracing (GIB) for
retrofitting the old buildings with a first soft-story issue. The basic idea behind this method …