Diffusion MRI of the breast: Current status and future directions
Diffusion‐weighted imaging (DWI) is increasingly being incorporated into routine breast MRI
protocols in many institutions worldwide, and there are abundant breast DWI indications …
protocols in many institutions worldwide, and there are abundant breast DWI indications …
[HTML][HTML] Complex diffusion-weighted image estimation via matrix recovery under general noise models
We propose a patch-based singular value shrinkage method for diffusion magnetic
resonance image estimation targeted at low signal to noise ratio and accelerated …
resonance image estimation targeted at low signal to noise ratio and accelerated …
Diffusion breast MRI: current standard and emerging techniques
AM Mendez, LK Fang, CH Meriwether… - Frontiers in …, 2022 - frontiersin.org
The role of diffusion weighted imaging (DWI) as a biomarker has been the subject of active
investigation in the field of breast radiology. By quantifying the random motion of water …
investigation in the field of breast radiology. By quantifying the random motion of water …
Quantitative comparison of reconstruction methods for intra-voxel fiber recovery from diffusion MRI
Validation is arguably the bottleneck in the diffusion magnetic resonance imaging (MRI)
community. This paper evaluates and compares 20 algorithms for recovering the local intra …
community. This paper evaluates and compares 20 algorithms for recovering the local intra …
Impact of MR acquisition parameters on DTI scalar indexes: a tractography based approach
Acquisition parameters play a crucial role in Diffusion Tensor Imaging (DTI), as they have a
major impact on the values of scalar measures such as Fractional Anisotropy (FA) or Mean …
major impact on the values of scalar measures such as Fractional Anisotropy (FA) or Mean …
Analysis and correction of gradient nonlinearity bias in apparent diffusion coefficient measurements
DI Malyarenko, BD Ross… - Magnetic resonance in …, 2014 - Wiley Online Library
Purpose Gradient nonlinearity of MRI systems leads to spatially dependent b‐values and
consequently high non‐uniformity errors (10–20%) in apparent diffusion coefficient (ADC) …
consequently high non‐uniformity errors (10–20%) in apparent diffusion coefficient (ADC) …
The effect of elimination of gibbs ringing, noise and systematic errors on the DTI metrics and tractography in a rat brain
W Mazur-Rosmus, AT Krzyżak - Scientific Reports, 2024 - nature.com
Diffusion tensor imaging (DTI) metrics and tractography can be biased due to low signal-to-
noise ratio (SNR) and systematic errors resulting from image artifacts and imperfections in …
noise ratio (SNR) and systematic errors resulting from image artifacts and imperfections in …
In vivo disentanglement of diffusion frequency‐dependence, tensor shape, and relaxation using multidimensional MRI
Diffusion MRI with free gradient waveforms, combined with simultaneous relaxation
encoding, referred to as multidimensional MRI (MD‐MRI), offers microstructural specificity in …
encoding, referred to as multidimensional MRI (MD‐MRI), offers microstructural specificity in …
Temperature and concentration calibration of aqueous polyvinylpyrrolidone (PVP) solutions for isotropic diffusion MRI phantoms
To use the “apparent diffusion coefficient”(D app) as a quantitative imaging parameter, well-
suited test fluids are essential. In this study, the previously proposed aqueous solutions of …
suited test fluids are essential. In this study, the previously proposed aqueous solutions of …
Simultaneous multislice echo planar imaging for accelerated diffusion-weighted imaging of malignant and benign breast lesions
Objectives Comparison of the diagnostic value of simultaneous multislice (SMS) accelerated
diffusion-weighted echo planar imaging (EPI) of malignant and benign lesions of the breast …
diffusion-weighted echo planar imaging (EPI) of malignant and benign lesions of the breast …