Cadmium zinc telluride and its use as a nuclear radiation detector material
We present a comprehensive review of the material properties of cadmium zinc telluride
(CZT, Cd1− xZnxTe) with zinc content x= 0.1–0.2. Particular emphasis is placed on those …
(CZT, Cd1− xZnxTe) with zinc content x= 0.1–0.2. Particular emphasis is placed on those …
Review of the Shockley–Ramo theorem and its application in semiconductor gamma-ray detectors
Z He - Nuclear Instruments and Methods in Physics Research …, 2001 - Elsevier
The Shockley–Ramo theorem is reviewed based on the conservation of energy. This review
shows how the energy is transferred from the bias supplies to the moving charge within a …
shows how the energy is transferred from the bias supplies to the moving charge within a …
Single charge carrier type sensing with a parallel strip pseudo-Frisch-grid CdZnTe semiconductor radiation detector
An improvement in gamma-ray energy resolution is demonstrated for a room-temperature
operated CdZnTe semiconductor detector that incorporates a parallel strip pseudo-Frisch …
operated CdZnTe semiconductor detector that incorporates a parallel strip pseudo-Frisch …
Electron trap** nonuniformity in high-pressure-Bridgman-grown CdZnTe
M Amman, JS Lee, PN Luke - Journal of Applied Physics, 2002 - pubs.aip.org
Gamma-ray spectroscopy is a valuable tool of science and technology. Many applications
for this tool are in need of a detector technology capable of achieving excellent energy …
for this tool are in need of a detector technology capable of achieving excellent energy …
Thin and thick films of metal oxides and metal phthalocyanines as gamma radiation dosimeters
K Arshak, A Arshak, S Zleetni… - IEEE Transactions on …, 2004 - ieeexplore.ieee.org
Numerous efforts were devoted to investigating the influence of radiation on metal oxides
and polymer materials for dosimetry applications. Metal oxides, such as NiO, LaFeO/sub 3 …
and polymer materials for dosimetry applications. Metal oxides, such as NiO, LaFeO/sub 3 …
CdZnTe semiconductor parallel strip Frisch grid radiation detectors
CdZnTe wide band gap compound semiconducting material offers promise as a room
temperature operated gamma ray spectrometer. Position-dependent free charge carrier …
temperature operated gamma ray spectrometer. Position-dependent free charge carrier …
A radioxenon detection system using CdZnTe, an array of SiPMs, and a plastic scintillator
SA Czyz, AT Farsoni - Journal of Radioanalytical and Nuclear Chemistry, 2017 - Springer
This paper presents the design and characterization of a prototype compact beta–gamma
radioxenon detection system that utilizes a coplanar CdZnTe crystal, an array of SiPMs, and …
radioxenon detection system that utilizes a coplanar CdZnTe crystal, an array of SiPMs, and …
135Xe measurements with a two-element CZT-based radioxenon detector for nuclear explosion monitoring
Measurement of elevated concentrations of xenon radioisotopes (131m Xe, 133m Xe, 133
Xe and 135 Xe) in the atmosphere has been shown to be a very powerful method for …
Xe and 135 Xe) in the atmosphere has been shown to be a very powerful method for …
Optimization criteria for coplanar-grid detectors
M Amman, PN Luke - 1998 IEEE Nuclear Science Symposium …, 1998 - ieeexplore.ieee.org
The coplanar-grid charge-sensing technique is a powerful method to achieve excellent
spectroscopic performance with large-volume, CdZnTe-based, gamma-ray detectors despite …
spectroscopic performance with large-volume, CdZnTe-based, gamma-ray detectors despite …
A CZT-based radioxenon detection system in support of the Comprehensive Nuclear-Test-Ban Treaty
In this work, a prototype radioxenon detection system was designed, developed and tested
at Oregon State University to study the response of CdZnTe (CZT) detectors to xenon …
at Oregon State University to study the response of CdZnTe (CZT) detectors to xenon …