Research on pseudo-static cyclic tests of precast concrete shear walls with vertical rebar lap** in grout-filled constrained hole

Q Gu, G Dong, X Wang, H Jiang, S Peng - Engineering Structures, 2019 - Elsevier
In this paper, the seismic behaviors of four precast shear wall specimens and one cast-in-
place shear wall specimen are investigated by pseudo-static test method. For the precast …

Seismic performance of precast concrete columns with prefabricated UHPC jackets in plastic hinge zone

D Guan, Z Chen, J Liu, Z Lin, Z Guo - Engineering Structures, 2021 - Elsevier
The plastic hinges of precast concrete columns with grouted sleeves commonly occur at the
column-footing connection regions, leading to difficulties in the repair and rehabilitation of …

Experimental study on seismic response of precast bridge piers with double-grouted sleeve connections

Y Liu, X Li, X Zheng, Z Song - Engineering Structures, 2020 - Elsevier
In recent years accelerated bridge construction (ABC) has become increasingly popular all
over the world because of its good quality, cost effectiveness and decreasing bridge …

Experimental study on a precast beam-column joint with double grouted splice sleeves

Z Lu, J Huang, S Dai, J Liu, M Zhang - Engineering Structures, 2019 - Elsevier
The construction speed and quality of precast frame structures are greatly influenced by
weld, tie, prestress, cast concrete requirements, etc. on site. To address these challenges, a …

Steel corrosion in precast reinforced concrete column-beam joint with grouted sleeve connections under chloride-rich environment

Y Wang, Y Zhao, L Peng, D Xu - Journal of Building Engineering, 2023 - Elsevier
Due to the existence of pump and vent holes, precast reinforced concrete (RC) structure with
grouted sleeve connections may have serious durability issues, which have almost never …

Microstructures and mechanical property of post-fire grouting sleeve connections considering concrete cover

Y Li, L Cheng, W Lei, Y Su, T Huang, Y Zhu… - … and Building Materials, 2023 - Elsevier
The performances of grouting sleeves for connections (GSCs) were critical for safety of
prefabricated concrete structures especially after building fire. The consideration of concrete …

Experimental investigation of mechanical behaviour of rebar in steel half-grouted sleeve connections with defects in water/binder ratio

J Chen, Z Wang, Z Liu, S Ju - Structures, 2020 - Elsevier
The mechanical behaviours of the rebar in steel half-grouted sleeve connections with
constructional deficiencies in the water/binder grout ratio were experimentally investigated …

Numerical study on the influence of defects in grouting on the mechanical properties of a full grouted sleeve connector

EK Kahama, X Fuzhe, DL M. Anglaaere - The Journal of Adhesion, 2022 - Taylor & Francis
The present article analyses the influence of defects in the bonding zone between the
reinforcement bar and the grout on the mechanical performance of the full-grouted sleeve …

Seismic behavior of precast columns with large-spacing and high-strength longitudinal rebars spliced by epoxy mortar-filled threaded couplers

W Han, Z Zhao, J Qian, Y Cui, S Liu - Engineering Structures, 2018 - Elsevier
An innovative precast concrete column system, which is expected to be emulative to
conventional cast-in-situ columns, is proposed in this paper. In this system, short novel …

[HTML][HTML] Experimental study and numerical simulation of a laminated reinforced concrete shear wall with a vertical seam

J Li, Y Wang, Z Lu, J Li - Applied Sciences, 2017 - mdpi.com
In this paper, 12 laminated reinforced concrete shear walls are designed for cyclic loading
tests. Seismic performance of laminated reinforced concrete shear walls with vertical seams …