Turnitin
降AI改写
早检测系统
早降重系统
Turnitin-UK版
万方检测-期刊版
维普编辑部版
Grammarly检测
Paperpass检测
checkpass检测
PaperYY检测
Stereotactic radiosurgery alone for multiple brain metastases? A review of clinical and technical issues
Over the past three decades several randomized trials have enabled evidence-based
practice for patients presenting with limited brain metastases. These trials have focused on …
practice for patients presenting with limited brain metastases. These trials have focused on …
Different dosimeters/detectors used in small-field dosimetry: Pros and cons
With the advent of complex and precise radiation therapy techniques, the use of relatively
small fields is needed. Using such field sizes can cause uncertainty in dosimetry; therefore …
small fields is needed. Using such field sizes can cause uncertainty in dosimetry; therefore …
Report of AAPM Task Group 155: megavoltage photon beam dosimetry in small fields and non‐equilibrium conditions
Small‐field dosimetry used in advance treatment technologies poses challenges due to loss
of lateral charged particle equilibrium (LCPE), occlusion of the primary photon source, and …
of lateral charged particle equilibrium (LCPE), occlusion of the primary photon source, and …
Performance evaluation of a CyberKnife® G4 image-guided robotic stereotactic radiosurgery system
The aim of the current work was to present the performance evaluation procedures
implemented at our department for the commissioning of a G4 CyberKnife system. This …
implemented at our department for the commissioning of a G4 CyberKnife system. This …
Validation of complex radiotherapy techniques using polymer gel dosimetry
CP Karger, A Elter, S Dorsch, P Mann… - Physics in Medicine …, 2024 - iopscience.iop.org
Modern radiotherapy delivers highly conformal dose distributions to irregularly shaped
target volumes while sparing the surrounding normal tissue. Due to the complex planning …
target volumes while sparing the surrounding normal tissue. Due to the complex planning …
Three-dimensional radiation dosimetry using polymer gel and solid radiochromic polymer: From basics to clinical applications
Y Watanabe, L Warmington… - World journal of …, 2017 - pmc.ncbi.nlm.nih.gov
Accurate dose measurement tools are needed to evaluate the radiation dose delivered to
patients by using modern and sophisticated radiation therapy techniques. However, the …
patients by using modern and sophisticated radiation therapy techniques. However, the …
Detector comparison for small field output factor measurements in flattening filter free photon beams
W Lechner, H Palmans, L Sölkner… - Radiotherapy and …, 2013 - Elsevier
Purpose The applicability of various detectors for small field dosimetry and whether there
are differences in the detector response when irradiated with FF-and FFF-beams was …
are differences in the detector response when irradiated with FF-and FFF-beams was …
Variation of for the small‐field dosimetric parameters percentage depth dose, tissue‐maximum ratio, and off‐axis ratio
Purpose: Evaluate the ability of different dosimeters to correctly measure the dosimetric
parameters percentage depth dose (PDD), tissue‐maximum ratio (TMR), and off‐axis ratio …
parameters percentage depth dose (PDD), tissue‐maximum ratio (TMR), and off‐axis ratio …
[HTML][HTML] Measurement of the radiation dose and radiation isocenter of the TrueBeam accelerator using 3D polymer gel dosimeters from the VIPAR family with different …
This work describes the measurements of the ionizing radiation dose and the determination
of the radiation isocenter using a tool consisting of three-dimensional polymer gel …
of the radiation isocenter using a tool consisting of three-dimensional polymer gel …
On the development of a VIPARnd radiotherapy 3D polymer gel dosimeter
This work presents an improvement of the VIPAR nd ('nd'stands for'normoxic, double', or
VIP) polymer gel dosimeter. The gel composition was altered by increasing the …
VIP) polymer gel dosimeter. The gel composition was altered by increasing the …