Turnitin
降AI改写
早检测系统
早降重系统
Turnitin-UK版
万方检测-期刊版
维普编辑部版
Grammarly检测
Paperpass检测
checkpass检测
PaperYY检测
B-spline parameterized joint optimization of reconstruction and k-space trajectories (bjork) for accelerated 2d mri
Optimizing k-space sampling trajectories is a promising yet challenging topic for fast
magnetic resonance imaging (MRI). This work proposes to optimize a reconstruction method …
magnetic resonance imaging (MRI). This work proposes to optimize a reconstruction method …
Diffusion imaging in the post HCP era
S Moeller, P Pisharady Kumar… - Journal of Magnetic …, 2021 - Wiley Online Library
Diffusion imaging is a critical component in the pursuit of develo** a better understanding
of the human brain. Recent technical advances promise enabling the advancement in the …
of the human brain. Recent technical advances promise enabling the advancement in the …
Stochastic optimization of three‐dimensional non‐Cartesian sampling trajectory
Purpose Optimizing three‐dimensional (3D) k‐space sampling trajectories is important for
efficient MRI yet presents a challenging computational problem. This work proposes a …
efficient MRI yet presents a challenging computational problem. This work proposes a …
MaxGIRF: image reconstruction incorporating concomitant field and gradient impulse response function effects
Purpose To develop and evaluate an improved strategy for compensating concomitant field
effects in non‐Cartesian MRI at the time of image reconstruction. Theory We present a …
effects in non‐Cartesian MRI at the time of image reconstruction. Theory We present a …
Rapid acquisition of the 3D MRI gradient impulse response function using a simple phantom measurement
J Rahmer, P Mazurkewitz, P Börnert… - Magnetic resonance in …, 2019 - Wiley Online Library
Purpose To provide a simple tool for rapid measurement of the 3D gradient modulation
transfer function (GMTF) of clinical MRI systems using a phantom. Knowledge of the transfer …
transfer function (GMTF) of clinical MRI systems using a phantom. Knowledge of the transfer …
Speech production real‐time MRI at 0.55 T
Purpose To demonstrate speech‐production real‐time MRI (RT‐MRI) using a contemporary
0.55 T system, and to identify opportunities for improved performance compared with …
0.55 T system, and to identify opportunities for improved performance compared with …
High‐quality FLORET UTE imaging for clinical translation
Purpose To develop a robust 3D ultrashort‐TE (UTE) protocol that can reproducibly provide
high‐quality images, assessed by the ability to yield clinically diagnostic images, and is …
high‐quality images, assessed by the ability to yield clinically diagnostic images, and is …
[HTML][HTML] Advances in spiral fMRI: A high-resolution study with single-shot acquisition
Spiral fMRI has been put forward as a viable alternative to rectilinear echo-planar imaging,
in particular due to its enhanced average k-space speed and thus high acquisition …
in particular due to its enhanced average k-space speed and thus high acquisition …
Direct imaging of white matter ultrashort T2∗ components at 7 Tesla
Purpose To demonstrate direct imaging of the white matter ultrashort T 2∗ components at 7
Tesla using inversion recovery (IR)-enhanced ultrashort echo time (UTE) MRI. To investigate …
Tesla using inversion recovery (IR)-enhanced ultrashort echo time (UTE) MRI. To investigate …
Cardiac real‐time MRI using a pre‐emphasized spiral acquisition based on the gradient system transfer function
Purpose Segmented Cartesian acquisition in breath hold represents the current gold
standard for cardiac functional MRI. However, it is also associated with long imaging times …
standard for cardiac functional MRI. However, it is also associated with long imaging times …