B-spline parameterized joint optimization of reconstruction and k-space trajectories (bjork) for accelerated 2d mri

G Wang, T Luo, JF Nielsen, DC Noll… - IEEE Transactions on …, 2022 - ieeexplore.ieee.org
Optimizing k-space sampling trajectories is a promising yet challenging topic for fast
magnetic resonance imaging (MRI). This work proposes to optimize a reconstruction method …

Diffusion imaging in the post HCP era

S Moeller, P Pisharady Kumar… - Journal of Magnetic …, 2021 - Wiley Online Library
Diffusion imaging is a critical component in the pursuit of develo** a better understanding
of the human brain. Recent technical advances promise enabling the advancement in the …

Stochastic optimization of three‐dimensional non‐Cartesian sampling trajectory

G Wang, JF Nielsen, JA Fessler… - Magnetic resonance in …, 2023 - Wiley Online Library
Purpose Optimizing three‐dimensional (3D) k‐space sampling trajectories is important for
efficient MRI yet presents a challenging computational problem. This work proposes a …

MaxGIRF: image reconstruction incorporating concomitant field and gradient impulse response function effects

NG Lee, R Ramasawmy, Y Lim… - Magnetic resonance …, 2022 - Wiley Online Library
Purpose To develop and evaluate an improved strategy for compensating concomitant field
effects in non‐Cartesian MRI at the time of image reconstruction. Theory We present a …

Rapid acquisition of the 3D MRI gradient impulse response function using a simple phantom measurement

J Rahmer, P Mazurkewitz, P Börnert… - Magnetic resonance in …, 2019 - Wiley Online Library
Purpose To provide a simple tool for rapid measurement of the 3D gradient modulation
transfer function (GMTF) of clinical MRI systems using a phantom. Knowledge of the transfer …

Speech production real‐time MRI at 0.55 T

Y Lim, P Kumar, KS Nayak - Magnetic Resonance in Medicine, 2024 - Wiley Online Library
Purpose To demonstrate speech‐production real‐time MRI (RT‐MRI) using a contemporary
0.55 T system, and to identify opportunities for improved performance compared with …

High‐quality FLORET UTE imaging for clinical translation

MM Willmering, G Krishnamoorthy… - Magnetic …, 2025 - Wiley Online Library
Purpose To develop a robust 3D ultrashort‐TE (UTE) protocol that can reproducibly provide
high‐quality images, assessed by the ability to yield clinically diagnostic images, and is …

[HTML][HTML] Advances in spiral fMRI: A high-resolution study with single-shot acquisition

L Kasper, M Engel, J Heinzle, M Mueller-Schrader… - NeuroImage, 2022 - Elsevier
Spiral fMRI has been put forward as a viable alternative to rectilinear echo-planar imaging,
in particular due to its enhanced average k-space speed and thus high acquisition …

Direct imaging of white matter ultrashort T2∗ components at 7 Tesla

M Mueller, N Egger, S Sommer, T Wilferth… - Magnetic resonance …, 2022 - Elsevier
Purpose To demonstrate direct imaging of the white matter ultrashort T 2∗ components at 7
Tesla using inversion recovery (IR)-enhanced ultrashort echo time (UTE) MRI. To investigate …

Cardiac real‐time MRI using a pre‐emphasized spiral acquisition based on the gradient system transfer function

P Eirich, T Wech, JF Heidenreich… - Magnetic resonance …, 2021 - Wiley Online Library
Purpose Segmented Cartesian acquisition in breath hold represents the current gold
standard for cardiac functional MRI. However, it is also associated with long imaging times …