[PDF][PDF] Assessment of stress shielding around a dental implant for variation of implant stiffness and parafunctional loading using finite element analysis
Purpose: The aim of this study was to evaluate the mechanical stimuli transfer at the bone-
implant interface via stress and strain energy density transfer parameters. This study also …
implant interface via stress and strain energy density transfer parameters. This study also …
The effect of material stiffness on dental implant stability–A finite element analysis
The perseverance of dental implant system in restoration of occlusion is highly dependent
on biomechanical overloading factors such as implant macro geometries, parafunctional …
on biomechanical overloading factors such as implant macro geometries, parafunctional …
Twist Blade Distributor in Fluidization Systems: Part 1–The Computational Procedure
Flowing gas in fluidized bed through selected inlet distributor may imparts a drag effect on
the particles, would cause an increase in gas flow, that maybe sufficient to rearrange the …
the particles, would cause an increase in gas flow, that maybe sufficient to rearrange the …
Simulation Based Optimization of Thin Wall Injection Molding Parameter Using Response Surface Methodology
Improper mold design or processing parameter setting could make a bad impact on the
appearance of molded part. It becomes more challenging if the ratio of the part size …
appearance of molded part. It becomes more challenging if the ratio of the part size …
Multi-Stage Swirling Fluidized Bed: Part 1-Numerical Analysis Procedure
Abstract Swirling Fluidized Bed (SFB) is a system that possess a plenum chamber and
distributor air gap which leading up to dispersion of the airflow to the bed. The current SFB is …
distributor air gap which leading up to dispersion of the airflow to the bed. The current SFB is …
Optimisation of Process Parameters in Plastic Injection Moulding Simulation for Blower Impeller's Fan Using Response Surface Methodology
Injection moulding process parameters such as moulding temperature, melt temperature,
injection pressure, and injection time have a direct impact on the quality and cost of polymer …
injection pressure, and injection time have a direct impact on the quality and cost of polymer …
[PDF][PDF] INFLUENCE OF PARAFUNCTIONAL LOADING CONDITIONS ON THE BIOMECHANICAL BEHAVIOUR OF DENTAL IMPLANT
Dental implant success is strongly linked to technical overloading variables like implant
material, implant macro geometries, and parafunctional oral behaviours. The configurations …
material, implant macro geometries, and parafunctional oral behaviours. The configurations …
Twist Blade Distributor in Fluidization Systems: Part 2–The Air Flow Characteristics
This study examines the findings of numerical analysis studies that were conducted to
determine how the arrangement of the blade distributors in a fluidization system affects the …
determine how the arrangement of the blade distributors in a fluidization system affects the …
Multi-Stage Swirling Fluidized Bed: Part 2-The Velocity Distribution
This task involved numerical analysis study to investigate the air flow distribution affected by
blade distributor arrangement of Multi-Stage Swirling Fluidized Bed (SFB). The current …
blade distributor arrangement of Multi-Stage Swirling Fluidized Bed (SFB). The current …
Biomechanical assessment of different surgical approaches of zygomatic implant placement on prosthesis stress
The treatment of severely atrophic posterior maxillae without bone augmentation by using
zygomatic implants has received a major attention in prosthodontics due to great implant …
zygomatic implants has received a major attention in prosthodontics due to great implant …