Low‐field MRI: An MR physics perspective

JP Marques, FFJ Simonis… - Journal of magnetic …, 2019 - Wiley Online Library
Historically, clinical MRI started with main magnetic field strengths in the∼ 0.05–0.35 T
range. In the past 40 years there have been considerable developments in MRI hardware …

Brain imaging with portable low-field MRI

WT Kimberly, AJ Sorby-Adams, AG Webb… - Nature reviews …, 2023 - nature.com
The advent of portable, low-field MRI (LF-MRI) heralds new opportunities in neuroimaging.
Low power requirements and transportability have enabled scanning outside the controlled …

[BOOK][B] Electromagnetic analysis and design in magnetic resonance imaging

J ** - 2018 - taylorfrancis.com
This book presents a comprehensive treatment of electromagnetic analysis and design of
three critical devices for an MRI system-the magnet, gradient coils, and radiofrequency (RF) …

[HTML][HTML] A bi-planar coil system for nulling background magnetic fields in scalp mounted magnetoencephalography

N Holmes, J Leggett, E Boto, G Roberts, RM Hill… - NeuroImage, 2018 - Elsevier
Abstract Small, commercially-available Optically Pumped Magnetometers (OPMs) can be
used to construct a wearable Magnetoencephalography (MEG) system that allows large …

Gradient coil design: a review of methods

R Turner - Magnetic resonance imaging, 1993 - Elsevier
Methods of coil design for MRI gradient coils and other purposes are discussed. The
conflicting requirements for satisfactory gradient coil performance are described and …

Balanced, bi-planar magnetic field and field gradient coils for field compensation in wearable magnetoencephalography

N Holmes, TM Tierney, J Leggett, E Boto, S Mellor… - Scientific reports, 2019 - nature.com
To allow wearable magnetoencephalography (MEG) recordings to be made on
unconstrained subjects the spatially inhomogeneous remnant magnetic field inside the …

Theory of gradient coil design methods for magnetic resonance imaging

SS Hidalgo‐Tobon - Concepts in Magnetic Resonance Part A, 2010 - Wiley Online Library
The process to produce an MR image includes nuclear alignment, RF excitation, spatial
encoding, and image formation. In simple terms, an magnetic resonance imaging (MRI) …

Apparatus and methods for delivery of transcranial magnetic stimulation

P Fox, J Lancaster - US Patent 7,087,008, 2006 - Google Patents
Disclosed are apparatus and methods for delivery of tran Scranial magnetic stimulation. The
apparatus includes a TMS coil which when energized generates an electric field …

Minimum energy MRI gradient coils of general geometry

S Pissanetzky - Measurement Science and Technology, 1992 - iopscience.iop.org
The author presents a new method for the design of gradient coil systems for magnetic
resonance imaging (MRI) with minimum energy. The new method eliminates previous …

Iterative optimization algorithm to design biplanar coils for dynamic magnetoencephalography

Z Ding, Z Huang, M Pang, B Han - IEEE Transactions on …, 2022 - ieeexplore.ieee.org
In this article, an iterative optimization algorithm is proposed to design biplanar coils, which
is used for dynamic magnetoencephalography to compensate for residual fields in the …