Low‐field MRI: An MR physics perspective
Historically, clinical MRI started with main magnetic field strengths in the∼ 0.05–0.35 T
range. In the past 40 years there have been considerable developments in MRI hardware …
range. In the past 40 years there have been considerable developments in MRI hardware …
Brain imaging with portable low-field MRI
The advent of portable, low-field MRI (LF-MRI) heralds new opportunities in neuroimaging.
Low power requirements and transportability have enabled scanning outside the controlled …
Low power requirements and transportability have enabled scanning outside the controlled …
[BOOK][B] Electromagnetic analysis and design in magnetic resonance imaging
J ** - 2018 - taylorfrancis.com
This book presents a comprehensive treatment of electromagnetic analysis and design of
three critical devices for an MRI system-the magnet, gradient coils, and radiofrequency (RF) …
three critical devices for an MRI system-the magnet, gradient coils, and radiofrequency (RF) …
[HTML][HTML] A bi-planar coil system for nulling background magnetic fields in scalp mounted magnetoencephalography
Abstract Small, commercially-available Optically Pumped Magnetometers (OPMs) can be
used to construct a wearable Magnetoencephalography (MEG) system that allows large …
used to construct a wearable Magnetoencephalography (MEG) system that allows large …
Gradient coil design: a review of methods
R Turner - Magnetic resonance imaging, 1993 - Elsevier
Methods of coil design for MRI gradient coils and other purposes are discussed. The
conflicting requirements for satisfactory gradient coil performance are described and …
conflicting requirements for satisfactory gradient coil performance are described and …
Balanced, bi-planar magnetic field and field gradient coils for field compensation in wearable magnetoencephalography
To allow wearable magnetoencephalography (MEG) recordings to be made on
unconstrained subjects the spatially inhomogeneous remnant magnetic field inside the …
unconstrained subjects the spatially inhomogeneous remnant magnetic field inside the …
Theory of gradient coil design methods for magnetic resonance imaging
SS Hidalgo‐Tobon - Concepts in Magnetic Resonance Part A, 2010 - Wiley Online Library
The process to produce an MR image includes nuclear alignment, RF excitation, spatial
encoding, and image formation. In simple terms, an magnetic resonance imaging (MRI) …
encoding, and image formation. In simple terms, an magnetic resonance imaging (MRI) …
Apparatus and methods for delivery of transcranial magnetic stimulation
Disclosed are apparatus and methods for delivery of tran Scranial magnetic stimulation. The
apparatus includes a TMS coil which when energized generates an electric field …
apparatus includes a TMS coil which when energized generates an electric field …
Minimum energy MRI gradient coils of general geometry
S Pissanetzky - Measurement Science and Technology, 1992 - iopscience.iop.org
The author presents a new method for the design of gradient coil systems for magnetic
resonance imaging (MRI) with minimum energy. The new method eliminates previous …
resonance imaging (MRI) with minimum energy. The new method eliminates previous …
Iterative optimization algorithm to design biplanar coils for dynamic magnetoencephalography
Z Ding, Z Huang, M Pang, B Han - IEEE Transactions on …, 2022 - ieeexplore.ieee.org
In this article, an iterative optimization algorithm is proposed to design biplanar coils, which
is used for dynamic magnetoencephalography to compensate for residual fields in the …
is used for dynamic magnetoencephalography to compensate for residual fields in the …