Bubble lift-off size in forced convective subcooled boiling flow

R Situ, T Hibiki, M Ishii, M Mori - International Journal of Heat and Mass …, 2005 - Elsevier
Forced convective subcooled boiling flow experiments were conducted in a BWR-scaled
vertical upward annular channel. Water was used as the testing fluid, and the tests were …

A mini-review on population balance model for gas-liquid subcooled boiling flow in nuclear industry

G Hu, Y Ma, H Zhang, Q Liu - Annals of Nuclear Energy, 2021 - Elsevier
The application of the population balance model (PBM) in the gas–liquid subcooled boiling
flow is of an emerging interest in the recent years. In this study, theoretical models …

Bubble departure frequency in forced convective subcooled boiling flow

R Situ, M Ishii, T Hibiki, JY Tu, GH Yeoh… - International Journal of …, 2008 - Elsevier
Forced convective subcooled boiling flow experiments were conducted in a vertical upward
annular channel. Water was used as the testing fluid, and the tests were performed at …

Review of Available Data for Validation of Nuresim Two‐Phase CFD Software Applied to CHF Investigations

D Bestion, H Anglart, D Caraghiaur… - … and Technology of …, 2009 - Wiley Online Library
The NURESIM Project of the 6th European Framework Program initiated the development of
a new‐generation common European Standard Software Platform for nuclear reactor …

Characteristics of the local bubble parameters of a subcooled boiling flow in an annulus

BJ Yun, BU Bae, DJ Euh, GC Park, CH Song - Nuclear Engineering and …, 2010 - Elsevier
An experimental study on the subcooled boiling phenomena was carried out in the SUBO
(SUbcooled BOiling) test facility under steam-water flow condition. The test section is a …

Flow structure of subcooled boiling water flow in a subchannel of 3× 3 rod bundles

BJ Yun, GC Park, JE Julia, T Hibiki - Journal of nuclear science …, 2008 - Taylor & Francis
In this paper, the interfacial flow structure of subcooled water boiling flow in a subchannel of
3× 3 rod bundles is presented. The 9 rods are positioned in a quadrangular assembly with a …

Development of interfacial area transportequation

M Ishii, S Kim, J Kelly - Nuclear Engineering and Technology, 2005 - dbpia.co.kr
The interfacial area transport equation dynamically models the changes in interfacial
structures along the flow field by mechanistically modeling the creation and destruction of …

Interfacial area transport of vertical upward steam–water two-phase flow in an annular channel at elevated pressures

B Ozar, CS Brooks, T Hibiki, M Ishii - International Journal of Heat and Mass …, 2013 - Elsevier
The interfacial area transport of vertical, upward, steam-water two-phase flows in a vertical
annular channel has been investigated. The inner and outer diameters of the annular …

PTV experiments of subcooled boiling flow through a vertical rectangular channel

CE Estrada-Perez, YA Hassan - International Journal of Multiphase Flow, 2010 - Elsevier
Time resolved Particle Tracking Velocimetry (PTV) experiments were carried out to
investigate turbulent, subcooled boiling flow of refrigerant HFE-301 through a vertical …

Experimental evaluation of local bubble parameters of subcooled boiling flow in a pressurized vertical annulus channel

IC Chu, SJ Lee, YJ Youn, JK Park, HS Choi… - … Engineering and Design, 2017 - Elsevier
Experiments were performed to quantify the local bubble parameters such as void fraction,
bubble velocity, interfacial area concentration, and Sauter mean diameter for the subcooled …