Engineered cementitious composite (ECC) strengthening of reinforced concrete structures: A state-of-the-art review

Z Hu, M Elchalakani, S Yehia, H Ran… - Journal of Building …, 2024 - Elsevier
Engineered cementitious composites (ECC) have been extensively studied and widely used
as a strengthening material due to its superior mechanical properties. Only few papers …

A proposed model to estimate shear contribution of FRP in strengthened RC beams in terms of Adaptive Neuro-Fuzzy Inference System

H Naderpour, SA Alavi - Composite Structures, 2017 - Elsevier
This study provides a fuzzy-based model for predicting the shear contribution of FRP in RC
beams strengthened by externally bonded FRP sheets. For this purpose, ultimate strain of …

Behavior of RC beams strengthened in shear with FRP and FRCM composites

JH Gonzalez-Libreros, LH Sneed, T D'Antino… - Engineering …, 2017 - Elsevier
This paper presents the results of an experimental campaign carried out to investigate the
behavior of reinforced concrete (RC) beams strengthened in shear with externally bonded …

Shear strength prediction of FRP-strengthened concrete beams using interpretable machine learning

C Wang, X Zou, LH Sneed, F Zhang, K Zheng… - … and Building Materials, 2023 - Elsevier
This study identified the factors affecting the contribution of externally bonded fiber
reinforced polymer (FRP) composite (V f) to the shear strength of reinforced concrete (RC) …

On the finite element modelling of RC beams shear-strengthened with FRP

GM Chen, JF Chen, JG Teng - Construction and Building Materials, 2012 - Elsevier
A significant number of studies have been conducted on the shear strengthening of
reinforced concrete (RC) beams with externally bonded fibre-reinforced polymer (FRP) …

Shear strengthening of reinforced concrete beams completely wrapped by large rupture strain (LRS) FRP

SJ Mei, YL Bai, JG Dai - Engineering Structures, 2024 - Elsevier
An experimental work on the shear strengthening of reinforced concrete (RC) beams
completely wrapped by large rupture strain (LRS) FRP is presented in this paper. A total of …

[HTML][HTML] Shear strength components of adjustable hybrid bonded CFRP shear-strengthened RC beams

Y Zhou, M Guo, L Sui, F **_FRP_Strip/links/5634dc5508aeb786b702c17c/Shear-Span-Depth-Ratio-Effect-on-Behavior-of-RC-Beam-Shear-Strengthened-with-Full-Wrap**-FRP-Strip.pdf?_sg%5B0%5D=started_experiment_milestone&origin=journalDetail" data-clk="hl=th&sa=T&oi=gga&ct=gga&cd=7&d=14177386252228689433&ei=hkm-Z7jCJ4C96rQP9sKS4Q4" data-clk-atid="Gf6Yb64xwMQJ" target="_blank">[PDF] researchgate.net

Shear span–depth ratio effect on behavior of RC beam shear strengthened with full-wrap** FRP strip

W Li, CKY Leung - Journal of Composites for Construction, 2016 - ascelibrary.org
Shear span-to-effective depth ratio (av/d) is known to affect the shear behavior of RC
members. However, this effect has not been appropriately addressed in existing design …

Finite element modeling of debonding failures in FRP-strengthened RC beams: A dynamic approach

GM Chen, JG Teng, JF Chen, QG **ao - Computers & Structures, 2015 - Elsevier
This paper is concerned with the finite element simulation of debonding failures in FRP-
strengthened concrete beams. A key challenge for such simulations is that common solution …

Three-dimensional finite element modeling of debonding failure of skew FRP-bonded concrete joints

WH Liu, MF Kai, P Zhang, T Yu, JG Dai - Engineering Structures, 2024 - Elsevier
Despite the extensive investigations on the shear strengthening of reinforced concrete (RC)
beams using externally bonded fiber-reinforced polymer (EB-FRP) composites, the critical …