Simple method for MR gradient system characterization and k‐space trajectory estimation

NO Addy, HH Wu, DG Nishimura - Magnetic resonance in …, 2012 - Wiley Online Library
Fast imaging trajectories are used in MRI to speed up the acquisition process, but
imperfections in the gradient system create artifacts in the reconstructed images. Artifacts …

A new design and rationale for 3D orthogonally oversampled k‐space trajectories

JG Pipe, NR Zwart, EA Aboussouan… - Magnetic resonance …, 2011 - Wiley Online Library
A novel center‐out 3D trajectory for sampling magnetic resonance data is presented. The
trajectory set is based on a single Fermat spiral waveform, which is substantially …

Abdominal 4D flow MR imaging in a breath hold: combination of spiral sampling and dynamic compressed sensing for highly accelerated acquisition

H Dyvorne, A Knight-Greenfield, G Jajamovich, C Besa… - Radiology, 2015 - pubs.rsna.org
Purpose To develop a highly accelerated phase-contrast cardiac-gated volume flow
measurement (four-dimensional [4D] flow) magnetic resonance (MR) imaging technique …

Efficient sample density estimation by combining gridding and an optimized kernel

NR Zwart, KO Johnson, JG Pipe - Magnetic resonance in …, 2012 - Wiley Online Library
The reconstruction of non‐Cartesian k‐space trajectories often requires the estimation of
nonuniform sampling density. Particularly for 3D, this calculation can be computationally …

Single‐shot spiral imaging enabled by an expanded encoding model: D emonstration in diffusion MRI

BJ Wilm, C Barmet, S Gross, L Kasper… - Magnetic resonance …, 2017 - Wiley Online Library
Purpose The purpose of this work was to improve the quality of single‐shot spiral MRI and
demonstrate its application for diffusion‐weighted imaging. Methods Image formation is …

Time efficient 3D radial UTE sampling with fully automatic delay compensation on a clinical 3T MR scanner

KH Herrmann, M Krämer, JR Reichenbach - PLoS One, 2016 - journals.plos.org
This work's aim was to minimize the acquisition time of a radial 3D ultra-short echo-time
(UTE) sequence and to provide fully automated, gradient delay compensated, and therefore …

Whole-brain background-suppressed pCASL MRI with 1D-accelerated 3D RARE Stack-Of-Spirals readout

M Vidorreta, Z Wang, YV Chang, DA Wolk… - PloS one, 2017 - journals.plos.org
Arterial Spin Labeled (ASL) perfusion MRI enables non-invasive, quantitative
measurements of tissue perfusion, and has a broad range of applications including brain …

Evaluation of segmented 3D acquisition schemes for whole‐brain high‐resolution arterial spin labeling at 3 T

M Vidorreta, E Balteau, Z Wang, E De Vita… - NMR in …, 2014 - Wiley Online Library
Recent technical developments have significantly increased the signal‐to‐noise ratio (SNR)
of arterial spin labeled (ASL) perfusion MRI. Despite this, typical ASL acquisitions still …

Trajectory correction based on the gradient impulse response function improves high‐resolution UTE imaging of the musculoskeletal system

S Kronthaler, J Rahmer, P Börnert… - Magnetic …, 2021 - Wiley Online Library
Purpose UTE sequences typically acquire data during the ram** up of the gradient fields,
which makes UTE imaging prone to eddy current and system delay effects. The purpose of …

Feasibility of free‐breathing 19F MRI image acquisition to characterize ventilation defects in CF and healthy volunteers at wash‐in

SH Chung, KM Huynh, JL Goralski… - Magnetic resonance …, 2023 - Wiley Online Library
Purpose To explore the feasibility of measuring ventilation defect percentage (VDP) using
19F MRI during free‐breathing wash‐in of fluorinated gas mixture with postacquisition …