Parametric finite element analysis of intramedullary nail fixation of proximal femur fractures

SM Tucker, H Wee, E Fox, JS Reid… - Journal of Orthopaedic …, 2019 - Wiley Online Library
Proximal femur fracture fixation with intramedullary nailing relies on stability at the fracture
site and integrity of the fixation construct to achieve union. The biomechanics that dictate …

Biomechanical investigation of titanium elastic nail prebending for treating diaphyseal long bone fractures

YN Chen, PY Lee, CW Chang, YH Ho, YT Peng… - Australasian physical & …, 2017 - Springer
This study numerically investigated the deformation of titanium elastic nails prebent at
various degrees during implantation into the intramedullary canal of fractured bones and the …

Computational comparison of tibial diaphyseal fractures fixed with various degrees of prebending of titanium elastic nails and with and without end caps

YN Chen, PY Lee, CH Chang, CW Chang, YH Ho… - Injury, 2016 - Elsevier
Introduction Elastic stable intramedullary nailing (ESIN) is a treatment strategy for the
management of diaphyseal long-bone fractures in adolescents and children, but few studies …

Stress Analysis of the Radius and Ulna in Tennis at Different Flexion Angles of the Elbow

Y Chen, Q Du, X Yin, R Fu, Y Zhu - Mathematics, 2023 - mdpi.com
In this paper, based on the finite element method, the stresses of the radius and ulna are
analyzed at different flexion angles of the elbow when playing tennis. The finite element …

The biomechanical analysis of three-dimensional distal radius fracture model with different fixed splints

Z Hua, JW Wang, ZF Lu, JW Ma… - Technology and Health …, 2018 - content.iospress.com
BACKGROUND: The distal radius fracture is one of the common clinical fractures. At
present, there are no reports regarding application of the finite element method in studying …

[PDF][PDF] A numerical comparative analysis of ChM and Fixion nails for diaphyseal femur fractures

D Ivanov, Y Barabash, A Barabash - Acta of Bioengineering and …, 2016 - bibliotekanauki.pl
Purpose: Today intramedullary locked nails are widespread in treatment of diaphyseal long
bone fractures of the lower limb. However, such nails have a number of drawbacks …

Development of a Comprehensive Linear Finite Element Model of the Human Wrist Joint

A Mena, R Wollstein, J Yang - … and Information in …, 2024 - asmedigitalcollection.asme.org
This study presents a linear finite element model for the human wrist, constructed from a CT
scan of a 68-year-old male (type I wrist). This model intricately captures the bones, soft …

[PDF][PDF] Доклиническое исследование надежности интрамедуллярных стержней для остеосинтеза диафизарных переломов бедренной кости

АП Барабаш, ИА Норкин, ЮА Барабаш… - Вестник …, 2016 - vestnikdgma.ru
Резюме Целью исследования явилось построение ЗD модели «бедренная кость–
фиксатор» и доклиническая сравнительная оценка биомеханических свойств …

Finite Element Modeling of the Human Wrist: A Review

A Mena, R Wollstein, J Baus, J Yang - Journal of Wrist Surgery, 2023 - thieme-connect.com
Background Understanding wrist biomechanics is important to appreciate and treat the wrist
joint. Numerical methods, specifically, finite element method (FEM), have been used to …

Preclinical biomechanics of a new intramedullary nail for femoral diaphyseal fractures

I Dmitry, B Anatoly, B Yuri - Russian Open Medical Journal, 2015 - cyberleninka.ru
This article presents new intramedullary (IM) nail design for femur diaphyseal fractures
osteosynthesis. Biomechanical comparison of the two IM nails (standard locking and new …