Scintillation detectors for x-rays

M Nikl - Measurement Science and Technology, 2006 - iopscience.iop.org
Recent research in the field of phosphor and scintillator materials and related detectors is
reviewed. After a historical introduction the fundamental issues are explained regarding the …

X-ray detectors for digital radiography

MJ Yaffe, JA Rowlands - Physics in Medicine & Biology, 1997 - iopscience.iop.org
Digital radiography offers the potential of improved image quality as well as providing
opportunities for advances in medical image management, computer-aided diagnosis and …

An accurate method for computer‐generating tungsten anode x‐ray spectra from 30 to 140 kV

JM Boone, JA Seibert - Medical physics, 1997 - Wiley Online Library
A tungsten anode spectral model using interpolating polynomials (TASMIP) was used to
compute x‐ray spectra at 1 keV intervals over the range from 30 kV to 140 kV. The TASMIP …

Spektr: a computational tool for x‐ray spectral analysis and imaging system optimization

JH Siewerdsen, AM Waese, DJ Moseley… - Medical …, 2004 - Wiley Online Library
A set of computational tools are presented that allow convenient calculation of x‐ray spectra,
selection of elemental and compound filters, and calculation of beam quality characteristics …

Electronic portal imaging devices: a review and historical perspective of contemporary technologies and research

LE Antonuk - Physics in Medicine & Biology, 2002 - iopscience.iop.org
A review of electronic portal imaging devices (EPIDs) used in external beam, megavoltage
radiation therapy is presented. The review consists of a brief introduction to the definition …

Empirical and theoretical investigation of the noise performance of indirect detection, active matrix flat‐panel imagers (AMFPIs) for diagnostic radiology

JH Siewerdsen, LE Antonuk, Y El‐Mohri… - Medical …, 1997 - Wiley Online Library
Noise properties of active matrix, flat‐panel imagers under conditions relevant to diagnostic
radiology are investigated. These studies focus on imagers based upon arrays with pixels …

A radiographic and tomographic imaging system integrated into a medical linear accelerator for localization of bone and soft-tissue targets

DA Jaffray, DG Drake, M Moreau, AA Martinez… - International Journal of …, 1999 - Elsevier
Purpose: Dose escalation in conformal radiation therapy requires accurate field placement.
Electronic portal imaging devices are used to verify field placement but are limited by the low …

A framework for noise‐power spectrum analysis of multidimensional images

JH Siewerdsen, IA Cunningham, DA Jaffray - Medical physics, 2002 - Wiley Online Library
A methodological framework for experimental analysis of the noise‐power spectrum (NPS)
of multidimensional images is presented that employs well‐known properties of the n …

Optimization of x‐ray imaging geometry (with specific application to flat‐panel cone‐beam computed tomography)

JH Siewerdsen, DA Jaffray - Medical physics, 2000 - Wiley Online Library
A theoretical method is presented that allows identification of optimal x‐ray imaging
geometry, considering the effects of x‐ray source distribution, imaging task, x‐ray scatter …

Signal-to-noise optimization of medical imaging systems

IA Cunningham, R Shaw - Journal of the optical society of America A, 1999 - opg.optica.org
Over recent decades a quiet revolution has taken place in the application of modern imaging
theory to many fields of applied imaging. Nowhere has this movement been more dramatic …