MRI‐related heating of implants and devices: a review
During an MRI scan, the radiofrequency field from the scanner's transmit coil, but also the
switched gradient fields, induce currents in any conductive object in the bore. This makes …
switched gradient fields, induce currents in any conductive object in the bore. This makes …
The physics of MRI safety
LP Panych, B Madore - Journal of Magnetic Resonance …, 2018 - Wiley Online Library
The main risks associated with magnetic resonance imaging (MRI) have been extensively
reported and studied; for example, everyday objects may turn into projectiles, energy …
reported and studied; for example, everyday objects may turn into projectiles, energy …
Improving safety of MRI in patients with deep brain stimulation devices
MRI is a valuable clinical and research tool for patients undergoing deep brain stimulation
(DBS). However, risks associated with imaging DBS devices have led to stringent …
(DBS). However, risks associated with imaging DBS devices have led to stringent …
Parallel transmission to reduce absorbed power around deep brain stimulation devices in MRI: Impact of number and arrangement of transmit channels
Purpose To assess the mean and variance performance of parallel transmission (pTx) coils
for reduction of the absorbed power around electrodes (APAE) in patients implanted with …
for reduction of the absorbed power around electrodes (APAE) in patients implanted with …
Controlling radiofrequency‐induced currents in guidewires using parallel transmit
M Etezadi‐Amoli, P Stang, A Kerr… - Magnetic resonance …, 2015 - Wiley Online Library
Purpose Elongated conductors, such as pacemaker leads, neurostimulator leads, and
conductive guidewires used for interventional procedures can couple to the MRI …
conductive guidewires used for interventional procedures can couple to the MRI …
A simple geometric analysis method for measuring and mitigating RF induced currents on deep brain stimulation leads by multichannel transmission/reception
The purpose of this work is to present a new method that can be used to estimate and
mitigate RF induced currents on Deep Brain Stimulation (DBS) leads. Here, we demonstrate …
mitigate RF induced currents on Deep Brain Stimulation (DBS) leads. Here, we demonstrate …
Parallel transmission medical implant safety testbed: Real‐time mitigation of RF induced tip heating using time‐domain E‐field sensors
L Winter, B Silemek, J Petzold, H Pfeiffer… - Magnetic …, 2020 - Wiley Online Library
Purpose To implement a modular, flexible, open‐source hardware configuration for parallel
transmission (pTx) experiments on medical implant safety and to demonstrate real‐time …
transmission (pTx) experiments on medical implant safety and to demonstrate real‐time …
A temperature sensor implant for active implantable medical devices for in vivo subacute heating tests under MRI
Purpose To introduce a temperature sensor implant (TSI) that mimics an active implantable
medical device (AIMD) for animal testing of MRI heating. Computer simulations and …
medical device (AIMD) for animal testing of MRI heating. Computer simulations and …
Wireless resonant circuits printed using aerosol jet deposition for MRI catheter tracking
Interventional magnetic resonance imaging (MRI) could allow for diagnosis and immediate
treatment of ischemic stroke; however, such endovascular catheter-based procedures under …
treatment of ischemic stroke; however, such endovascular catheter-based procedures under …
MR safety watchdog for active catheters: Wireless impedance control with real‐time feedback
Purpose To dynamically minimize radiofrequency (RF)‐induced heating of an active
catheter through an automatic change of the termination impedance. Methods A prototype …
catheter through an automatic change of the termination impedance. Methods A prototype …