Dam** techniques for grid-connected voltage source converters based on LCL filter: An overview

CC Gomes, AF Cupertino, HA Pereira - Renewable and Sustainable …, 2018 - Elsevier
Distributed generation systems have been expanded considerably in recent years. These
systems are generally based on power electronics converters, whose switching harmonics …

Topologies, generalized designs, passive and active dam** methods of switching ripple filters for voltage source inverter: A comprehensive review

M Büyük, A Tan, M Tümay, KÇ Bayındır - Renewable and Sustainable …, 2016 - Elsevier
Switching ripple filters (SRF) is one of the significant part of grid connected voltage source
converters (VSC) that have been a backbone of the most of renewable energy systems for …

Virtual-impedance-based control for voltage-source and current-source converters

X Wang, YW Li, F Blaabjerg… - IEEE Transactions on …, 2014 - ieeexplore.ieee.org
The virtual impedance concept is increasingly used for the control of power electronic
systems. Generally, the virtual impedance loop can either be embedded as an additional …

Design and analysis of robust active dam** for LCL filters using digital notch filters

W Yao, Y Yang, X Zhang, F Blaabjerg… - IEEE Transactions on …, 2016 - ieeexplore.ieee.org
Resonant poles of LCL filters may challenge the entire system stability especially in digital-
controlled pulse width modulation (PWM) inverters. In order to tackle the resonance issues …

Filter-based active dam** of voltage source converters with $ LCL $ filter

J Dannehl, M Liserre, FW Fuchs - IEEE Transactions on …, 2010 - ieeexplore.ieee.org
Pulsewidth modulation (PWM) voltage source converters are becoming a popular interface
to the power grid for many applications. Hence, issues related to the reduction of PWM …

Full feedforward of grid voltage for grid-connected inverter with LCL filter to suppress current distortion due to grid voltage harmonics

X Wang, X Ruan, S Liu, KT Chi - IEEE Transactions on Power …, 2010 - ieeexplore.ieee.org
The grid-connected inverter with an LCL filter has the ability of attenuating the high-
frequency current harmonics. However, the current distortion caused by harmonics in the …

Systematic design of the lead-lag network method for active dam** in LCL-filter based three phase converters

R Peña-Alzola, M Liserre, F Blaabjerg… - IEEE Transactions …, 2013 - ieeexplore.ieee.org
Three-phase active rectifiers guarantee sinusoidal input currents and unity power factor at
the price of a high switching frequency ripple. To adopt an LCL-filter, instead of an L-filter …

Active dam** of LCL-filter resonance based on virtual resistor for PWM rectifiers—Stability analysis with different filter parameters

C Wessels, J Dannehl, FW Fuchs - 2008 IEEE Power …, 2008 - ieeexplore.ieee.org
This publication presents the investigation of active dam** of resonance oscillations with
virtual resistor for grid-connected PWM rectifiers with LCL-filter for different filter parameters …